Honeywell Heat/1Cool User Guide - Page 69

Function, Existing Control Terminal Designation, Electronic Replacement or Upgrade, Chronotherm IV

Page 69 highlights

Existing Control Terminal Designation HONEYWELL UNIVERSAL THERMOSTATS Electronic Replacement or Upgrade Chronotherm IV Q6300A1002 Q6300A1010 T8611R1000 T8611R1158 T8611G1004 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Function Common · X X C B C C C C Power R R R R R R R R Compressor Y 1st Stage - Heat Auxiliary W2 Heat Y Y1 Y1 Y ³ ³ ³ W1 W1 W1 - W2 W2 W2 W2 Y ³ W1 W2 Y1 ³ W1 W2 Y1/W1 - ² Aux. Fan G G G G G C/O Valve B B B H B Heat G G G or » » B B O/B O/B C/O Valve O O O O O Cool O or » O O/B O/B » System Monitor/ L L º L º L º L º L Sytem Defrost ¶ L ¶ L Em. Heat E E E E E E E E Multiple - Heat Loads LED Indication - - ´ ´ ´ ´ ¿ - - - X1 X2 - ´ ´ ¿ X1 X2 - Defrost P - P - - - - - ² 2nd Stage - - - - - - - W2 Compressor 2nd Stage - - - - - - - Y2 Cool ¾ ³ Remove factory-installed jumper for independent first stage heat and cool operation. · Terminal must be connected to the transformer common. » Configure O/B (select models) in Installer Setup. ¿ Optional LED indication activated with completed circuit on X1 and X2 terminals. ´ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ² When W2 is not used, configure W2 cycle rate to NC. ¶ LED is energized when terminal is powered. º L terminal is powered continuously when thermostat is in Em. Ht. position. ¾ If Y2 is used, T8611M may be used as replacement. M13244 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER T874R1491/Q674L1553 T874G1600/Q674F1428 T8085R1015/Q682L1010 T8300A1003/Q6300A1010 T8300A1011/Q6300A1002 T8300A1045/Q6300A1002 T8300A1029/Q6300A1036 T8300A1037/Q6300A1044 T8300B1001/Q6300B1000 T8611R1000 T8611G1004 70-6627 • 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
67
HONEYWELL
UNIVERSAL THERMOSTATS
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
T874R1491/Q674L1553
T874G1600/Q674F1428
T8085R1015/Q682L1010
T8300A1003/Q6300A1010
T8300A1011/Q6300A1002
T8300A1045/Q6300A1002
T8300A1029/Q6300A1036
T8300A1037/Q6300A1044
T8300B1001/Q6300B1000
T8611R1000
T8611G1004
T8011R1006
T8011R1014
Function
Q6300A1010
T8611R1000
T8611R1158
T8611G1004
PC8900/
W8900B1002
Existing Control Terminal Designation
Electronic Replacement or Upgrade
A
Remove factory-installed jumper for independent first stage heat and cool
operation.
B
Terminal must be connected to the transformer common.
C
Configure O/B (select models) in Installer Setup.
D
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
Common
B
Power
Compressor
1st Stage
Heat
Auxiliary
Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
Sytem Defrost
Em. Heat
Multiple
Heat Loads
LED
Indication
Defrost
2nd Stage
Compressor
2nd Stage
Cool
I
M13244
E
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
F
When W2 is not used, configure W2 cycle rate to NC.
G
LED is energized when terminal is powered.
H
L terminal is powered continuously when thermostat is in Em. Ht. position.
I
If Y2 is used, T8611M may be used as replacement.
A
A
A
A
C
F
C
C
C
E
F
D
E
E
E
E
H
E
H
G
H
G
T8611G2002
T8611G2028
H
Q6300A1002
A
D
X
X
C
B
C
C
C
C
R
R
R
R
R
R
R
R
Y
Y
Y1
Y1
Y
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
B
B
B
H
B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O/B
L
L
L
L
L
L
L
L
E
E
E
E
E
E
E
E
X1
X2
X1
X2
P
P
W2
Y2
Chronotherm IV