Honeywell Heat/1Cool User Guide - Page 42

Function, Electromechanical, Chronotherm, Electronic Replacement or Upgrade

Page 42 highlights

BARD Models: 24UHPQC, 30UHPQC, 42UHPQC, 48UHPQB, 48UHPQB-B, 48UHPQC-B, 60UHPQC-B Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1712 Y594R1425 Y5Y9549G41G4174619 T8T681611G11R0100400 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Existing Function Terminals Common ´ C or X X or X1 Power Rh or R R Rc Compressor Y Y 1st Stg. Heat - - Aux. Heat W2 W2 Fan G G C/O Valve or B W1 B Heat C/O Valve O O Cool System Monitor/ L System Defrost X R Y ² W1 W2 G B X R Y1 ² W1 W2 G B C R or Y1 Y ² W1 W2 G B O O O ¾ ¾ µ L X1 L C C C C C R R R R R Y ² W1 W2 Y1 ² W1 W2 Y ² W1 W2 Y1 ² W1 W2 Y1/W1 - Aux. · G G G ³ or B B O/B B ³ or O O O/B O G ³ or B O/B G ³ O/B or ³ O O/B ³ O/B µ ¾ µ L L L ¾ ¾ L L EM. Heat E E E E Multiple Aux. W3 W3 W3 W3 Heat Loads ¿ LED Indication - - X2 º X2 º 2nd Stage - - - - Compressor ³ Configure O/B (select models) in Installer Setup. · When W2 is not used, configure W2 cycle rate to NC. » If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ¿ Terminal is for multiple second stage heating loads such as contactors, sequencers, or relays. E E E E E E » » » » » » ¶ X1 X2 - - - X1 X2 - · - - - - - W2 ´ Terminal X (C, X1) must be connected to transformer. ² Do not remove factory-installed jumper. ¶ Optional CHECK LED on T8611G1004. See Fig. 26. º Field-installed X2 to X jumper (provided). ¾ LED is energized when terminal is powered. µ L terminal is powered continuously when thermostat is in Em. Ht. position. M13145 70-6627 • 40 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER T872N1036/Q672F1299 T874R1129/Q674L1181 T872N1164/Q672L1185 T874R1152/Q674L1207 T874N1024/Q674F1261

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
40
BARD
Models: 24UHPQC, 30UHPQC, 42UHPQC, 48UHPQB, 48UHPQB-B, 48UHPQC-B, 60UHPQC-B
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
T872N1036/Q672F1299
T872N1164/Q672L1185
T874N1024/Q674F1261
T874R1129/Q674L1181
T874R1152/Q674L1207
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1712
T8611R1000
T8611G1004
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
Common
E
Power
Compressor
1st Stg. Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
EM. Heat
Multiple Aux.
Heat Loads
D
LED
Indication
2nd Stage
Compressor
M13145
I
A
J
I
C
A
I
J
A
A
A
A
A
Configure O/B (select models) in Installer Setup.
B
When W2 is not used, configure W2 cycle rate to NC.
C
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
D
Terminal is for multiple second stage heating loads such as contactors,
sequencers, or relays.
B
G
E
Terminal X (C, X1) must be connected to transformer.
F
Do not remove factory-installed jumper.
G
Optional CHECK LED on T8611G1004. See Fig. 26.
H
Field-installed X2 to X jumper (provided).
I
LED is energized when terminal is powered.
J
L terminal is powered continuously when thermostat is in Em. Ht. position.
or
X1
Rc
C
C
C
C
C
F
F
F
F
F
F
F
I
I
J
H
H
B
Chronotherm
IV
C
or
X
X
X
X
C
C
C
C
C
C
Rh
or
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
B
or
W1
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
L
L
X1
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
E
W3
W3
W3
W3
X2
X2
X1
X2
X1
X2
W2
Y594R1425
Y594G1419
Y594G1476