Honeywell Heat/1Cool User Guide - Page 86

Pe Series Equipment

Page 86 highlights

MAGIC CHEF "PE" SERIES EQUIPMENT Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1712 Y594R1425 Y5Y95494G1G4174619 T8T681611G11R0100400 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Existing Function Terminals Common ² C X X X C C C C C C Power R R · Compressor Y Y 1st Stage - - Heat Aux. Heat W W2 R R R Y Y1 Y1 or Y ¶ ¶ ¶ W1 W1 W1 W2 W2 W2 R Y ¶ W1 R Y1 ¶ W1 R Y ¶ W1 W2 W2 W2 R R Y1 ¶ W1 Y1/W1 - ¹ W2 Aux. Fan G G G G C/O Valve - Heat B B B C/O Valve O Cool O O O System Monitor/ ´ X1 L System Defrost ᕤ EM. Heat E E E E G B O Lƹ E G G G ³ or B B O/B B ³ or O O O/B O G ³ or B O/B ³ or O O/B G ³ O/B ³ O/B ƹ Ƹ L L ƹ L Ƹ L Ƹ L E E E E E Multiple Aux. - Heat Loads » LED Indication - W3 W3 W3 µ µ µ - X2 ¾ ¸ X1 X2 X1 X2 º - - µ µ µ ¸ - X1 X2 - 2nd Stage Compressor - - - - ³ Configure O/B (select models) in Installer Setup. · Both first stage heat and cool are connected to Y terminal. » Terminal is for multiple second stage loads such as contactors, sequencers, or relays. ¿ If provided on original equipment. ´ Relay (typically R8222B1067) required if outdoor section has reset shunt relay and malfunction light indication is desired on thermostat. See page 11. ² Terminal C (X) must be connected to transformer common. ¶ Do not remove factory-installed jumper. ¹ - - - - - W2 º Optional CHECK LED on T8611G1004. Connect X1 to X1 on control terminal; jumper X2 to R. ¾ Field-installed X2 to X jumper (provided). µ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ¸ Optional LED indication activated with completed circuit on X1 and X2 terminals. ¹ When W2 is not used, configure W2 cycle rate to NC. Ƹ LED is energized when terminal is powered. ƹ L terminal is powered continuously in Emergency Heat Position. M13168 70-6627 • 84

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
84
MAGIC CHEF
“PE” SERIES EQUIPMENT
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1712
T8411R1002
T8411R1028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Configure O/B (select models) in Installer Setup.
B
Both first stage heat and cool are connected to Y terminal.
C
Terminal is for multiple second stage loads such as contactors, sequencers,
or relays.
D
If provided on original equipment.
E
Relay (typically R8222B1067) required if outdoor section has reset shunt
relay and malfunction light indication is desired on thermostat. See page 11.
F
Terminal C (X) must be connected to transformer common.
G
Do not remove factory-installed jumper.
Common
F
Power
Compressor
1st Stage
Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
EM. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
2nd Stage
Compressor
M13168
H
Optional CHECK LED on T8611G1004. Connect X1 to X1 on control
terminal; jumper X2 to R.
I
Field-installed X2 to X jumper (provided).
J
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
K
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
L
When W2 is not used, configure W2 cycle rate to NC.
M
LED is energized when terminal is powered.
N
L terminal is powered continuously in Emergency Heat Position.
B
N
M
M
M
N
N
L
G
E
4
H
K
I
A
A
A
A
A
A
G
G
G
G
G
G
J
J
J
J
J
J
K
T8611R1000
T8611G1004
T8511G1021
T8511G1047
T8611G2002
T8611G2028
L
C
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
X1
L
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
E
W3
W3
W3
X2
X1
X2
X1
X2
X1
X2
W2
Chronotherm
IV
Y594R1425
Y594G1419
Y594G1476