INTERCITY PRODUCTS/HEIL QUAKER/WHIRLPOOL/TEMPSTAR Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV AVAILNAOBTLE Y594R1425 Y5Y95494G1G4174619 T8611R1000 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Existing Function Terminals Common ³ X X X C C C C C C Power R Compressor Y 1st Stage W1 Heat Auxiliary W2 Heat R Y · W1 R Y1 · W1 W2 W2 R Y1 · W1 W2 R Y · W1 R Y1 · W1 W2 W2 R Y · W1 W2 R Y1 · W1 R ² Y1/W1 ¶ W2 Aux. NOT AVAILABLE Fan G C/O Valve B Heat C/O Valve O Cool System Monitor/ L System Defrost G G B B O O º L G G G G G G or ¿ or ¿ ¿ B B B O/B B B O/B O/B or ¿ ¿ or ¿ O O O O/B O O O/B O/B ¾ L ¾ º L L ¾ L º L º L Em. Heat E E E E E E E E E Multiple Aux. W3 Heat Loads » W3 W3 ´ ´ ´ ´ ´ ´ LED Indication - X2 X1 X2 - - - - X1 X2 - Defrost P - - P - - - - - 2nd Stage - Compressor ¶ - - - - - - - W2 ³ Terminal X (C) must be connected to transformer common. · Remove factory-installed Y1 (Y) to W1 jumper. » Terminal is for multiple auxiliary heat loads such as contactors, sequencers or relays. ¿ Configure O/B (select models) in Installer Setup. ´ If multiple auxiliary heat loads are used, connect to W2 (W8900B) terminal. ² If separate Y1 and W1 terminals are required, install R8222D1014. See page 12. ¶ When W2 is not used, configure W2 cycle rate to NC. º LED is energized when terminal is powered. ¾ L terminal is powered continuously when thermostat is in Em. Ht. position. M13159 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T8611R1190 (HQ1149375HW) T874R1947/Q674L1819 (HQ1149406HW/HQ1149407HW) 70-6627 • 68

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
68
INTERCITY PRODUCTS/HEIL QUAKER/WHIRLPOOL/TEMPSTAR
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T8611R1190 (HQ1149375HW)
T874R1947/Q674L1819 (HQ1149406HW/HQ1149407HW)
T8011R1006
T8011R1014
Function
Existing
Terminals
NOT
AVAILABLE
T8611R1000
T8411R1002
T8411R1028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Terminal X (C) must be connected to transformer common.
B
Remove factory-installed Y1 (Y) to W1 jumper.
C
Terminal is for multiple auxiliary heat loads such as contactors, sequencers or
relays.
D
Configure O/B (select models) in Installer Setup.
E
If multiple auxiliary heat loads are used, connect to W2 (W8900B) terminal.
Common
A
Power
Compressor
1st Stage
Heat
Auxiliary
Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
Em. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
Defrost
2nd Stage
Compressor
G
M13159
B
F
If separate Y1 and W1 terminals are required, install R8222D1014. See
page 12.
G
When W2 is not used, configure W2 cycle rate to NC.
H
LED is energized when terminal is powered.
I
L terminal is powered continuously when thermostat is in Em. Ht. position.
B
B
B
B
D
D
D
D
D
D
F
E
E
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
Y
Y
Y1
Y1
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
L
L
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
W3
W3
W3
X2
X1
X2
X1
X2
P
P
W2
E
E
E
E
B
B
T8511G1021
T8511G1047
T8611G2002
T8611G2028
I
I
I
H
H
H
H
G
Chronotherm
IV
NOT AVAILABLE
Y594R1425
Y594G1419