Honeywell Heat/1Cool User Guide - Page 52

Evcon/coleman

Page 52 highlights

EVCON/COLEMAN MODELS: 3200, 3300 ³ Chronotherm® III Electronic Replacement or Upgrade T861³1R1000 T8T481³411R11R0120802 T8T081³011R11R0110406 Function Common · Power 1st Stg. Heat Compressor Aux. Heat Fan Existing Terminals BLCK (2) RED (1) (5) W (6) Y (4) W2 G C R W1 » Y1 W2 G C R W1 » Y1 W2 G C R W1 » Y1 W2 G C/O Valve B O Cool (5) O O C/O Valve - B Heat B B ³ System Monitor/ System Defrost ³ (3) E L L L EM. Heat ³ ³ (10) A E E E LED Indication (3) X - - - ³ R8222B1067 relays required to operate system. Equipment requires normally energized emergency heat. See page 10 for wiring diagram. · Terminal must be connected to the transformer common. » Remove factory-installed jumper on Model 3200. Do not remove factoryinstalled jumper on Model 3300. M13203 70-6627 • 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
50
EVCON/COLEMAN
MODELS: 3200, 3300
A
T8011R1006
T8011R1014
A
Function
Existing
Terminals
T8611R1000
A
T8411R1002
T8411R1028
A
Chronotherm
®
III
Electronic Replacement or Upgrade
Common
B
Power
1st Stg. Heat
Compressor
Aux. Heat
Fan
C/O Valve
Cool
C/O Valve
Heat
System Monitor/
System Defrost
A
EM. Heat
A
LED Indication
M13203
(10)
(3)
(5)
(3)
(4)
(6)
(2)
(1)
(5)
C
C
C
A
A
A
R8222B1067 relays required to operate system. Equipment requires normally
energized emergency heat. See page 10 for wiring diagram.
B
Terminal must be connected to the transformer common.
C
Remove factory-installed jumper on Model 3200. Do not remove factory-
installed jumper on Model 3300.
BLCK
C
C
C
RED
R
R
R
W
W1
W1
W1
Y
Y1
Y1
Y1
W2
W2
W2
W2
G
G
G
G
B
O
O
O
B
B
B
E
L
L
L
A
E
E
E
X