Honeywell Heat/1Cool User Guide - Page 13

Fig. 10. Relay wiring connections for Magic Chef equipment PE Series. Requires R8222B1067 Relay

Page 13 highlights

HEAT PUMP THERMOSTAT CROSS REFERENCE/SELECTION GUIDE Existing Control Equipment Function Terminal Designation Power VR System Monitor L New Terminal Designation R L or X1 or F M13238 Fig. 9. Relay wiring connections for Lennox equipment (HP16, HP19, HP21, HP22 Direct Replacements). Requires R8222B1067 Relay to operate the system monitor light (emergency heat LED) on TRADELINE replacement thermostats. Tape off if light is not desired. Existing Control Equipment Function Terminal Designation Power R System Monitor X1 New Terminal Designation R or L X1 M13239 Fig. 10. Relay wiring connections for Magic Chef equipment (PE Series). Requires R8222B1067 Relay if outdoor section has reset shunt relay and malfunction light indicator is desired on thermostat. Existing Control Equipment Function Terminal Designation Power or R1 R System Monitor or L X New Terminal Designation R or L X1 M13240 Fig. 11. Relay wiring connections for Mammoth. Requires R8222B1067 Relay if outdoor section has reset shunt relay and malfunction light indicator is desired on thermostat. 70-6627 • 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
11
Fig. 10. Relay wiring connections for Magic Chef equipment (PE Series). Requires R8222B1067 Relay
if outdoor section has reset shunt relay and malfunction light indicator is desired on thermostat.
Fig. 9. Relay wiring connections for Lennox equipment (HP16, HP19, HP21, HP22 Direct Replacements).
Requires R8222B1067 Relay to operate the system monitor light (emergency heat LED) on
TRADELINE replacement thermostats. Tape off if light is not desired.
Fig. 11. Relay wiring connections for Mammoth. Requires R8222B1067 Relay if outdoor
section has reset shunt relay and malfunction light indicator is desired on thermostat.
Equipment Function
Existing Control
Terminal Designation
Power
System Monitor
M13238
New Terminal
Designation
VR
R
L
L
or
X1
or
F
Equipment Function
Existing Control
Terminal Designation
Power
System Monitor
M13239
New Terminal
Designation
R
R
X1
L
or
X1
Equipment Function
Existing Control
Terminal Designation
Power
System Monitor
M13240
New Terminal
Designation
R1
or
R
R
L
or
X
L
or
X1
HEAT PUMP THERMOSTAT CROSS REFERENCE/SELECTION GUIDE