Honeywell Heat/1Cool User Guide - Page 50

Existing, Terminals, AVAILABLE, PC8900

Page 50 highlights

ECONAR Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV AVAILNAOBTLE Y594R1425 Y5Y9549G41G4174619 T8611R1000 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Existing Function Terminals Common ³ X X X C C C C C C Power R Compressor Y 1st Stg. Heat W1 Aux. Heat W2 R Y · W1 W2 R Y1 · W1 W2 R Y1 · W1 W2 R Y · W1 W2 R Y1 · W1 W2 R Y · W1 W2 R Y1 · W1 W2 R ² Y1/W1 - ¿ Aux. NOT AVAILABLE Fan G C/O Valve B Heat System Monitor/ L System Defrost G G B B º º L X1 G B ¾ L G G or ¶ B B O/B ¾ º L L G G G ¶ or ¶ B B O/B O/B ¾ º º L L L EM. Heat E Multiple Aux. W3 Heat Loads » C/O Valve O Cool E E W3 W3 O O E E E E E E ´ ´ ´ ´ ´ ´ or ¶ ¶ or ¶ O O O O/B O O O/B O/B LED Indication - X2 X2 2nd Stage - Compressor - - ³ Terminal X (C) must be connected to transformer common. · Remove factory-installed Y1 (Y) to W1 jumper. » Terminal is for multiple second stage loads such as contactors, sequencers, or relays. ¿ When W2 is not used, configure W2 cycle rate to NC. - - - - X1 X2 - ¿ - - - - - W2 ´ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ² Install R8222D1014 (see page 12) for separate Y1 and W1 terminals. ¶ Configure O/B (select models) in Installer Setup. º LED is energized when terminal is powered. ¾ L terminal is powered continuously when thermostat is in Em. Ht. position. M13153 70-6627 • 48 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER T874G1915/Q674F1410

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
48
ECONAR
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
T874G1915/Q674F1410
T8011R1006
T8011R1014
Function
Existing
Terminals
NOT
AVAILABLE
T8611R1000
T8411R1002
T8411R1028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
Common
A
Power
Compressor
1st Stg. Heat
Aux. Heat
Fan
C/O Valve
Heat
System Monitor/
System Defrost
EM. Heat
Multiple Aux.
Heat Loads
C
C/O Valve
Cool
LED
Indication
2nd Stage
Compressor
M13153
G
B
G
D
E
F
G
G
G
G
A
Terminal X (C) must be connected to transformer common.
B
Remove factory-installed Y1 (Y) to W1 jumper.
C
Terminal is for multiple second stage loads such as contactors, sequencers,
or relays.
D
When W2 is not used, configure W2 cycle rate to NC.
E
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
F
Install R8222D1014 (see page 12) for separate Y1 and W1 terminals.
G
Configure O/B (select models) in Installer Setup.
H
LED is energized when terminal is powered.
I
L terminal is powered continuously when thermostat is in Em. Ht. position.
B
B
B
B
B
B
E
E
E
E
E
T8511G1021
T8511G1047
T8611G2002
T8611G2028
D
H
I
H
I
H
H
H
I
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
Y
Y
Y1
Y1
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
L
L
X1
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
W3
W3
W3
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
X2
X2
X1
X2
W2
Chronotherm
IV
NOT AVAILABLE
Y594R1425
Y594G1419
Y594G1476