Honeywell Heat/1Cool User Guide - Page 19

Fig. 19. Internal schematic and typical wiring diagram for T841B1000., Fig. 20. Internal schematic - heat cool thermostat wiring

Page 19 highlights

HEAT PUMP THERMOSTAT CROSS REFERENCE/SELECTION GUIDE H1/C1 ANTICIPATOR H1 C1 FALL FAN SWITCH AUTO ON W1 HEAT RELAY 1 W2 HEAT RELAY 2 B HEAT CHANGEOVER VALVE G FAN RELAY H2 ANTICIPATOR H2 FALL SYSTEM SWITCH HEAT OFF COOL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. R L1 (HOT) L2 1 X Y1 COMPRESSOR CONTACTOR O COOL CHANGEOVER VALVE M6068A Fig. 19. Internal schematic and typical wiring diagram for T841B1000. FALL H1 H1 ANTICIPATOR H2 FALL RESET HEATER RISE CHANGEOVER C1 ANTICIPATOR FAN SWITCH AUTO ON SYSTEM SWITCH EM .HT. AUTO OFF C815A OUTDOOR THERMISTOR T FAN RELAY G CHANGEOVER VALVE O R X2 OUTDOOR THERMOSTAT W AUX. HT. LED (GREEN) B EM. HT. LED (RED) F AUX. HT. RELAY Y RISE C1 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Fig. 20. Internal schematic and typical wiring diagram for Y594G1161. L1 (HOT) L2 1 M1593 70-6627 • 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
17
Fig. 19. Internal schematic and typical wiring diagram for T841B1000.
H2
FALL
H1
FALL
C1
L1
(HOT)
L2
1
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
H1/C1
ANTICIPATOR
H2 ANTICIPATOR
SYSTEM
SWITCH
COOL
OFF
HEAT
COOL CHANGEOVER VALVE
COMPRESSOR
CONTACTOR
FAN RELAY
HEAT CHANGEOVER
VALVE
HEAT RELAY 1
HEAT RELAY 2
FAN SWITCH
AUTO
ON
M6068A
W1
W2
B
G
R
X
Y1
O
HEAT PUMP THERMOSTAT CROSS REFERENCE/SELECTION GUIDE
Fig. 20. Internal schematic and typical wiring diagram for Y594G1161.
H1
FALL
H2
FALL
CHANGEOVER
RISE
C1
RISE
L1
(HOT)
L2
1
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
C1
ANTICIPATOR
OFF
AUTO
EM .HT.
SYSTEM
SWITCH
AUX. HT.
LED (GREEN)
EM. HT.
LED (RED)
AUX. HT.
RELAY
OUTDOOR
THERMOSTAT
CHANGEOVER
VALVE
FAN RELAY
C815A OUTDOOR
THERMISTOR
T
G
O
R
X2
W
B
F
Y
FAN
SWITCH
AUTO
ON
H1 ANTICIPATOR
RESET
HEATER
M1593