Texas Instruments TINSPIRE Data Collection Guidebook - Page 17
Setting a Time Based Collection Mode - calculator review
View all Texas Instruments TINSPIRE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Setting a Time Based Collection Mode The Time Based collection mode captures data using timing as a guide. Set this mode to collect either samples per second (Rate) or seconds per sample (Interval) to determine how often data points are collected. Rate and Interval are simply reciprocals of each other. To set the Collection Mode to Time Based: 1. Click Experiment > Collection Mode > Time Based. The Configure Time Based Data Collection window opens with either Interval or Rate selected. (It uses previous settings as the opening value.) or Rate (samples/second) Interval (seconds/sample) 2. Select Rate or Interval from the list. • Rate (samples/second): Type the number of samples per second. The interval is calculated. • Interval (seconds per sample): Type the number of seconds per sample. The rate is calculated. 3. Type the number of seconds the data collection should last in the Duration field. 4. Review the value in the Number of points field to ensure the rate and duration are reasonable. Note: The Number of points field is a calculated field. This value is determined by the formula, Rate * Duration + 1. Important: Collecting too many data points impacts system performance. 5. Select one of the following, if needed. Performing an Experiment 13