ZyXEL VES1724-56B2 User Guide - Page 123
Table 44, Label, Description
View all ZyXEL VES1724-56B2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
Chapter 9 VDSL Setup The device sends an alarm trap and generates a syslog entry when the thresholds of the alarm profile are exceeded. Figure 66 VDSL Line Alarm Profile Setup The following table describes the labels in this screen. Table 44 VDSL Line Alarm Profile Setup LABEL Name VTUC VTUR 15 Minute FECS Threshold 15 Minute ES Threshold 15 Minute SES Threshold 15 Minute LOSS Threshold 15 Minute UAS Threshold 15 Minute LOFS Threshold 15 Minute LPRS Threshold 15 Minute FailedFullInt Threshold DESCRIPTION Enter a descriptive name for identification purposes. Configure the thresholds in this column for the Switch (VTUC). Configure the thresholds in this column for CPE devices (VTUR). Enter the number of Forward Error Correction Seconds (FECS) that are permitted to occur within 15 minutes. Enter the number of Errored Seconds (ES) that are permitted to occur within 15 minutes. Enter the number of Severely Errored Seconds (SES) that are permitted to occur within 15 minutes. Enter the number of Loss Of Signals Seconds (LOSS) that are permitted to occur within 15 minutes. Enter the number of UnAvailable Seconds (UAS) that are permitted to occur within 15 minutes. Enter the number of Loss Of Framing Seconds (LOFS) that are permitted to occur within 15 minutes. Enter the number of times a Loss of PoweR Seconds (LPRS) is permitted to occur within 15 minutes. Enter the number of times a full initialization is allowed to fail within 15 minutes. VES1724-56 User's Guide 123