ZyXEL VES1724-56B2 User Guide - Page 341
Table 160, Option, Object Label, Object Id, Description, Table 161
View all ZyXEL VES1724-56B2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 341 highlights
Chapter 37 Access Control Table 160 SNMP Switch Traps (continued) OPTION OBJECT LABEL OBJECT ID DESCRIPTION mactable MacTableFullEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2.1 This trap is sent when more than 99% of the MAC table is used. MacTableFullEventClear or 1.3.6.1.4.1.890.1.5.12.46.45.2.2 This trap is sent when less than 95% of the MAC table is used. rmon RmonRisingAlarm 1.3.6.1.2.1.16.0.1 This trap is sent when a variable goes over the RMON "rising" threshold. RmonFallingAlarm 1.3.6.1.2.1.16.0.2 This trap is sent when the variable falls below the RMON "falling" threshold. Table 161 SNMP VDSL Traps OPTION OBJECT LABEL OBJECT ID alarmprofile xdsl2LinePerfFECSThresh 1.3.6.1.2.1.10.251.0.1 Xtuc xdsl2LinePerfFECSThresh Xtur xdsl2LinePerfESThreshXt uc 1.3.6.1.2.1.10.251.0.2 1.3.6.1.2.1.10.251.0.3 xdsl2LinePerfESThreshXt 1.3.6.1.2.1.10.251.0.4 ur xdsl2LinePerfSESThresh 1.3.6.1.2.1.10.251.0.5 Xtuc xdsl2LinePerfSESThresh 1.3.6.1.2.1.10.251.0.6 Xtur xdsl2LinePerfLOSSThres 1.3.6.1.2.1.10.251.0.7 hXtuc xdsl2LinePerfLOSSThres hXtur xdsl2LinePerfUASThresh Xtuc 1.3.6.1.2.1.10.251.0.8 1.3.6.1.2.1.10.251.0.9 xdsl2LinePerfUASThresh 1.3.6.1.2.1.10.251.0.10 Xtur xdsl2LinePerfCodingViola 1.3.6.1.2.1.10.251.0.11 tionsThreshXtuc xdsl2LinePerfCodingViola 1.3.6.1.2.1.10.251.0.12 tionsThreshXtur xdsl2LinePerfCorrectedT 1.3.6.1.2.1.10.251.0.13 hreshXtuc DESCRIPTION This trap is sent when the Switch detects that the number of FEC seconds exceeds the threshold. This trap is sent when the number of FEC seconds in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of errored seconds exceeds the threshold. This trap is sent when the number of errored seconds in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of severely errored seconds exceeds the threshold. This trap is sent when the number of severely errored seconds in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of LOS seconds exceeds the threshold. This trap is sent when the number of LOS seconds in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of unavailable seconds exceeds the threshold. This trap is sent when the number of unavailable seconds in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of coding violations exceeds the threshold.. This trap is sent when the number of coding violations in CPE side exceeds the threshold. This trap is sent when the Switch detects that the number of corrected blocks (FEC events) exceeds the threshold. VES1724-56 User's Guide 341