Campbell Scientific CSAT3B CSAT3B Three-Dimensional Sonic Anemometer - Page 26

CSAT3B Three-Dimensional Sonic Anemometer, HUB-SDM8 for multiple CSAT3B connections

Page 26 highlights

CSAT3B Three-Dimensional Sonic Anemometer distance from the datalogger, the HUB-SDM8 can be placed near the CSAT3Bs with a single SDM cable extended from the hub to the datalogger. This decreases the total network cable length, which limits signal attenuation. The HUB-SDM8 has eight terminal strips and features spring-loaded guillotine terminals for easy wiring. It comes in a watertight enclosure and includes a Ubolt for mounting to a vertical pipe or mast. An SDM Cable (CABLE5CBL-L; see Section 5.2.4.4, SDM Cable CABLE5CBL-L) should be ordered to connect the HUB-SDM8 to a datalogger and a power supply. FIGURE 5-10. HUB-SDM8 for multiple CSAT3B connections with SDM communications 5.2.4.4 SDM Cable CABLE5CBL-L The SDM cable, CABLE5CBL-L, is a 22 AWG, five-conductor cable with a Santoprene jacket and an aluminum Mylar® shield. By default, the conductors are stripped and tinned. The CABLE5CBL-L is used to connect the power and SDM connection from a HUB-SDM8 to the power and SDM connections on a power source and datalogger. 5.2.4.5 HUB-CPI The HUB-CPI (pn 30692) allows up to eight CPI devices to be connected together in parallel. In the case of the CSAT3B, up to seven CSAT3Bs, or CSAT3B daisy-chains using CSAT3BCBL3 cables, may be connected in parallel to the HUB-CPI. The remaining port may be used with a CAT5e or CAT6 Ethernet cable (see Section 5.2.4.4, SDM Cable CABLE5CBL-L) to connect the HUB-CPI to the CPI port on a datalogger such as the CR6. The HUB-CPI (shown in FIGURE 5-11) is not weatherproof and should be housed in an enclosure, typically alongside the datalogger. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

CSAT3B Three-Dimensional Sonic Anemometer
distance from the datalogger, the HUB-SDM8 can be placed near the
CSAT3Bs with a single SDM cable extended from the hub to the datalogger.
This decreases the total network cable length, which limits signal attenuation.
The HUB-SDM8 has eight terminal strips and features spring-loaded guillotine
terminals for easy wiring.
It comes in a watertight enclosure and includes a U-
bolt for mounting to a vertical pipe or mast.
An SDM Cable (CABLE5CBL-L;
see Section 5.2.4.4,
SDM Cable CABLE5CBL-L
) should be ordered to connect
the HUB-SDM8 to a datalogger and a power supply.
FIGURE 5-10.
HUB-SDM8 for multiple CSAT3B connections with SDM
communications
5.2.4.4 SDM Cable CABLE5CBL-L
The SDM cable, CABLE5CBL-L, is a 22 AWG, five-conductor cable with a
Santoprene jacket and an aluminum Mylar
®
shield. By default, the conductors
are stripped and tinned.
The CABLE5CBL-L is used to connect the power and SDM connection from a
HUB-SDM8 to the power and SDM connections on a power source and
datalogger.
5.2.4.5 HUB-CPI
The HUB-CPI (pn 30692) allows up to eight CPI devices to be connected
together in parallel. In the case of the CSAT3B, up to seven CSAT3Bs, or
CSAT3B daisy-chains using CSAT3BCBL3 cables, may be connected in
parallel to the HUB-CPI.
The remaining port may be used with a CAT5e or
CAT6 Ethernet cable (see Section 5.2.4.4,
SDM Cable CABLE5CBL-L
) to
connect the HUB-CPI to the CPI port on a datalogger such as the CR6.
The HUB-CPI (shown in FIGURE 5-11) is not weatherproof and should be
housed in an enclosure, typically alongside the datalogger.