Campbell Scientific CSAT3B CSAT3B Three-Dimensional Sonic Anemometer - Page 32

CSAT3B Three-Dimensional Sonic Anemometer, Connecting CSAT3B using Device Configuration

Page 32 highlights

CSAT3B Three-Dimensional Sonic Anemometer 2. Connect the circular connector on the USB data cable included with the CSAT3B (pn 30179) to the port labelled USB on the back of the CSAT3B block. Connect the other end of the cable to a USB port on a PC. 3. Launch Device Configuration Utility (available on the included resource DVD or downloaded from www.campbellsci.com). 4. From the left side of the main screen, select the CSAT3B among the list of sensors. Select the appropriate communication port and baud rate (refer to the left side of FIGURE 7-1). 5. If this is the first time this PC has connected to a CSAT3B and depending on the PC settings, the USB driver may need to be manually installed. To do this, make sure the PC is connected to the internet and click on the install the USB driver link as shown in FIGURE 7-1). 6. Once the driver has been installed, if needed, press the Connect button at the bottom left of the window. FIGURE 7-1. Connecting CSAT3B using Device Configuration Utility 7. Once connected, the main screen will have a section with tabs to view the following four subscreens: Real-Time Data, Communication Settings, Measurement Settings, and Instrument ID. TABLE 7-1 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

CSAT3B Three-Dimensional Sonic Anemometer
2.
Connect the circular connector on the USB data cable included with
the CSAT3B (pn 30179) to the port labelled
USB
on the back of the
CSAT3B block.
Connect the other end of the cable to a USB port on
a PC.
3.
Launch
Device Configuration Utility
(available on the included
resource DVD or downloaded from
www.campbellsci.com
).
4.
From the left side of the main screen, select the CSAT3B among the
list of sensors.
Select the appropriate communication port and baud
rate (refer to the left side of FIGURE 7-1).
5.
If this is the first time this PC has connected to a CSAT3B and
depending on the PC settings, the USB driver may need to be
manually installed.
To do this, make sure the PC is connected to the
internet and click on the
install the USB driver
link as shown in
FIGURE 7-1).
6.
Once the driver has been installed, if needed, press the
Connect
button at the bottom left of the window.
FIGURE 7-1.
Connecting CSAT3B using Device Configuration Utility
7.
Once connected, the main screen will have a section with tabs to view
the following four subscreens:
Real-Time Data
,
Communication
Settings
,
Measurement Settings
, and
Instrument ID
.
TABLE 7-1