Campbell Scientific CSAT3B CSAT3B Three-Dimensional Sonic Anemometer - Page 51
CPI/RS-485 Communication Port Protocol, RS-485 Baud Rate, Unprompted Output Port, Unprompted Output
![]() |
View all Campbell Scientific CSAT3B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
CSAT3B Three-Dimensional Sonic Anemometer NOTE CPI/RS-485 Communication Port Protocol: RS-485 Enabled RS-485 Baud Rate: 115200 or other appropriate value Unprompted Output Port: RS-485 Port Unprompted Output Rate: 10, 20, 50 or 100 Hz Operating Mode: • Mode 3: Self-triggered | No filter | Unprompted output to PC, or • Mode 4: Self-triggered | Filtered | Unprompted output to PC (If Mode 4, select filter bandwidth.) To complete installation, connect a CSAT3BCBL2 to the Power/SDM port by screwing in the M16 connector into the port until tight. A CSAT3BCBL1 may also be used for power, but the SDM wires will not be used. The CSAT3BCSBL1 also has lighter gauge power wires, which increases voltage losses over long cable length, so it should only be used for shorter cable lengths. Next, connect a CSAT3BCBL3 cable to the CPI/RS-485 port in the same manner. If only one CSAT3B is being measured, the opposite end of the power cable should have pigtail wire leads, which may be connected to a 12 to 32 Vdc power supply, and the RS-485 cable should have pigtail wire leads for wiring to a connector on a PC (see FIGURE 7-16). Refer to TABLE 7-2 for a summary of the receive-and-transmit wiring. FIGURE 7-16. RS-485 cable connections 41
![](/manual_guide/products/campbell-scientific-csat3b-csat3b-threedimensional-sonic-anemometer-61e7b42/51.png)