Campbell Scientific CSAT3B CSAT3B Three-Dimensional Sonic Anemometer - Page 44

CSAT3B Three-Dimensional Sonic Anemometer

Page 44 highlights

CSAT3B Three-Dimensional Sonic Anemometer For an application that requires SDM communications from multiple CSAT3Bs in series, or with a daisy-chain topology, first connect to each CSAT3B as described in Section 7.1, Settings, to ensure each sensor has been assigned a unique SDM address. Connect a CSAT3BCBL1 to the Power/SDM port of the terminal CSAT3B. The opposite end will have an M16 connector that mates with one of the split M16 connectors on the Power/SDM splitters (pn 30293). Next, screw the side of the splitter with only one M16 connector to the Power/SDM port of the second CSAT3B. Connect another CSAT3BCBL1 to the splitter and down to the next CSAT3B. Continue the daisy-chain until the last CSAT3B. The final CSAT3BCBL1 should have pigtail wire ends to connect to the SDM and 12 V ports of a datalogger. If several CSAT3Bs using SDM communications are being connected in parallel or with a star topology, connect a CSAT3BCBL1 cable to the Power/SDM port of each CSAT3B, and connect the other wire leads on the pigtail end of the cables to a HUB-SDM8 bus (see Section 5.2.4.3, HUBSDM8). Connect the wires so that all wires of a common color or signal are on the same rail. Then, use a CABLE5CBL with pigtail wire leads to connect the HUB-SDM to the SDM and 12 V ports of a datalogger. 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

CSAT3B Three-Dimensional Sonic Anemometer
For an application that requires SDM communications from multiple
CSAT3Bs in series, or with a daisy-chain topology, first connect to each
CSAT3B as described in Section 7.1,
Settings
,
to ensure each sensor has been
assigned a unique SDM address. Connect a CSAT3BCBL1 to the
Power/SDM
port of the terminal CSAT3B.
The opposite end will have an
M16 connector that mates with one of the split M16 connectors on the
Power/SDM splitters (pn 30293).
Next, screw the side of the splitter with only
one M16 connector to the
Power/SDM
port of the second CSAT3B.
Connect
another CSAT3BCBL1 to the splitter and down to the next CSAT3B.
Continue the daisy-chain until the last CSAT3B.
The final CSAT3BCBL1
should have pigtail wire ends to connect to the
SDM
and
12 V
ports of a
datalogger.
If several CSAT3Bs using SDM communications are being connected in
parallel or with a star topology, connect a CSAT3BCBL1 cable to the
Power/SDM
port of each CSAT3B, and connect the other wire leads on the
pigtail end of the cables to a HUB-SDM8 bus (see Section 5.2.4.3,
HUB-
SDM8
).
Connect the wires so that all wires of a common color or signal are on the
same rail.
Then, use a CABLE5CBL with pigtail wire leads to connect the
HUB-SDM to the
SDM
and
12 V
ports of a datalogger.