Campbell Scientific CSAT3B CSAT3B Three-Dimensional Sonic Anemometer - Page 34

TABLE 7-1., CSAT3B Settings and Status Values in, Subscreen, Setting or Status, Value, Options,

Page 34 highlights

CSAT3B Three-Dimensional Sonic Anemometer TABLE 7-1. CSAT3B Settings and Status Values in Device Configuration Utility Subscreen Measurement Settings Instrument ID Setting or Status Value Unprompted Output Rate Operating Mode Filter Bandwidth Anemometer Serial Number Options 10 Hz1 20 Hz 50 Hz 100 Hz Mode 1: Dataloggertriggered | No filter | Datalogger-prompted output1 Mode 2: Selftriggered | Filtered | Datalogger-prompted output Mode 3: Selftriggered | No filter | Unprompted output to PC Mode 4: Selftriggered | Filtered | Unprompted output to PC 5 Hz 10 Hz 20 Hz 25 Hz Serial Number1 User ID String Blank1 Factory ID String Blank1 OS Version - OS Date - 1 Denotes a factory default setting Description Identifies the rate at which to output unprompted data Identifies the source of the measurement trigger, whether a low pass filter will be applied, and the output mode (see section 8.2 for more details on operating mode) The cut-off frequency of the low pass filter The serial number of the CSAT3B A unique identifier in addition to the serial number that the user may assign A unique identifier in addition to the serial number that the factory may assign The version number of the CSAT3B operating system The date the loaded operating system was built NOTE Factory defaults for all setting may be restored by clicking the Factory Defaults button at the bottom of the screen in the Device Configuration Utility. NOTE The SDM communications port is always enabled. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

CSAT3B Three-Dimensional Sonic Anemometer
TABLE 7-1.
CSAT3B Settings and Status Values in
Device Configuration Utility
Subscreen
Setting or Status
Value
Options
Description
Unprompted
Output Rate
10 Hz
1
20 Hz
50 Hz
100 Hz
Identifies the rate at which to output
unprompted data
Measurement
Settings
Operating Mode
Mode 1
:
Datalogger-
triggered | No filter |
Datalogger-prompted
output
1
Mode 2
:
Self-
triggered | Filtered |
Datalogger-prompted
output
Mode 3
:
Self-
triggered | No filter |
Unprompted output to
PC
Mode 4
:
Self-
triggered | Filtered |
Unprompted output to
PC
Identifies the source of the measurement
trigger, whether a low pass filter will be
applied, and the output mode (see section
8.2 for more details on operating mode)
Filter Bandwidth
5 Hz
10 Hz
20 Hz
25 Hz
The cut-off frequency of the low pass filter
Instrument ID
Anemometer
Serial Number
Serial Number
1
The serial number of the CSAT3B
User ID String
Blank
1
A unique identifier in addition to the serial
number that the user may assign
Factory ID String
Blank
1
A unique identifier in addition to the serial
number that the factory may assign
OS Version
-
The version number of the CSAT3B
operating system
OS Date
-
The date the loaded operating system was
built
1
Denotes a factory default setting
Factory defaults for all setting may be restored by clicking the
Factory Defaults
button at the bottom of the screen in the
Device
Configuration Utility
.
The SDM communications port is always enabled.
NOTE
NOTE
24