Problem: Scan button cannot be selected ➤Solution 1: A scan cannot be performed if the scan area is set too small (less than 64 x 64 pixels). Increase the size of the scan area ➤Solution 2: A scan cannot be performed unless a scan area is specified. Specify a scan area ➤Solution 3: A scan cannot be performed if the required memory is larger than the free memory. Change the resolution (➜ p. 19) or scan area (➜ p. 30) until the required memory is lower Problem: The "Insufficient Memory" error message appears when scanning ➤Solution 1: Select the smallest possible area and rescan ➤Solution 2: Lower the resolution and magnification settings for the output device to the lowest possible values (➜ p. 19) ➤Solution 3: Rescan after closing all the application programs other than the one used to start Plug-in Module CS-U ➤Solution 4: Rescan after you have restarted the application program used to start Plug-in Module CS-U ➤Solution 5: Quit the application program used to start Plug-in Module CS-U and increase the memory allocated to it. Click the application program icon once. Then open the [File] menu, choose [Get Info], and choose [Memory] from the submenu. Increase the memory in the Preferred Size box to at least 12000 K. ➤Solution 6: Increase the amount of RAM as required Problem: The [Image] menu [ColorSync] option cannot be used in Plug-in Module CS-U ➤Solution: ColorSync is not recognized after Mac OS upgraded to Version 9 after Plug-in Module CS-U was installed onto Mac OS 8.5 or 8.6. Reinstall Plug-in Module CS-U (➜ p. 6) 59