Dell PowerEdge FX2 Dell PowerEdge FX2 and FX2s Enclosure Owners Manual - Page 130
cfgChassisRedundancyPolicy (Read/Write), cfgChassisInMaxPowerCapacity (Read Only)
View all Dell PowerEdge FX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Default 100 cfgChassisRedundancyPolicy (Read/Write) Description Sets the redundancy policy of the chassis. Legal Values • 0 (no redundancy) • 1 (Grid redundancy) • 3 ( Redundancy Alerting Only) Default 3 ( Redundancy Alerting Only) cfgChassisInMaxPowerCapacity (Read Only) Description Indicates the total chassis power budget (in watts) available for chassis operation. Legal Values None Default None cfgChassisInRedundancyReserve (Read Only) Description Indicates the amount of redundant power (in Watts) in reserve that can be utilized in the event of an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to 0 (no redundancy). Legal Values 0 (disabled) 1 (enabled) Default None cfgChassisPowerClear (Write Only) Description Resets cfgChassisMinPower and cfgChassisMaxPowerCapacity, when set to 1. Legal Values None Default None 130