Dell PowerEdge FX2 Dell PowerEdge FX2 and FX2s Enclosure Owners Manual - Page 35

getdcinfo, Server, Presence, DC1 Type, DC1 State

Page 35 highlights

racadm getconfig -f myrac.cfg • Displays a list of the available configuration groups on CMC in an alphabetical order. racadm getconfig -h • Displays the configuration properties for the user named root. racadm getconfig -u root • Displays the user group instance at index 2 with verbose information for the property values. racadm getconfig -g cfgUserAdmin -i 2 -v getdcinfo Description Synopsis Input Displays general I/O module and daughter card configuration information. Only the CMC controls daughtercards. To use this subcommand, you must have the CMC Login User privilege. NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the chassis is on stand-by power, iDRACs on the server modules remain turned off and thus are unable to report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface until iDRAC on the server is turned on. racadm getdcinfo -n - Displays the model names for the daughter cards in servers. Example The following example is for a system with multi-slot servers. racadm getdcinfo Group A I/O Type : Gigabit Ethernet Group B I/O Type : PCIe Group C I/O Type : PCIe switch-1 Gigabit Ethernet OK Master server-1 server-2 server-3 Present PCIe Not Present None Present PCIe OK PCIe N/A None OK None OK N/A N/A 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

racadm getconfig -f myrac.cfg
Displays a list of the available configuration groups on CMC in an
alphabetical order.
racadm getconfig -h
Displays the configuration properties for the user named
root
.
racadm getconfig -u root
Displays the user group instance at index 2 with verbose information for
the property values.
racadm getconfig -g cfgUserAdmin -i 2 -v
getdcinfo
Description
Displays general I/O module and daughter card configuration information.
Only the CMC controls daughtercards.
To use this subcommand, you must have the
CMC Login User
privilege.
NOTE:
Fabric verification for server DCs is performed only when the
chassis is turned on. When the chassis is on stand-by power, iDRACs
on the server modules remain turned off and thus are unable to report
the server's DC fabric type. The DC fabric type may not be reported in
the CMC user interface until iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
Input
-n
— Displays the model names for the daughter cards in servers.
Example
The following example is for a system with multi-slot servers.
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : PCIe
Group C I/O Type : PCIe
<
IO#
>
<
Type
>
<
State
>
<
Role
>
switch-1
Gigabit Ethernet
OK
Master
<
Server#
>
<
Presence
>
<
DC1 Type
>
<
DC1 State
>
<
DC2 Type
>
<
DC2 State
>
server-1
Present
PCIe
OK
PCIe
OK
server-2
Not Present
None
N/A
None
N/A
server-3
Present
PCIe
OK
None
N/A