Dell PowerEdge FX2 Dell PowerEdge FX2 and FX2s Enclosure Owners Manual - Page 67

ping, racdump, Description, Synopsis, Example, CMC Login User, Input

Page 67 highlights

ping Description Synopsis ping6 Description Synopsis Example racdump Description Synopsis Input Verifies that the destination IP address is reachable from CMC with the current routing-table contents. A destination IP address is required. An ICMP echo packet is sent to the destination IP address based on the current routing-table contents. To use this subcommand for CMC, you must have the Administrator privilege for CMC. racadm ping Verifies that the destination IPv6 address is reachable from an CMC, or with the current routing-table contents. A destination IPv6 address is required. An ICMP echo packet is sent to the destination IPv6 address on the basis of current routing-table contents. To use this subcommand for CMC, you must have the Administrator privilege. racadm ping6 racadm iping6 10.9.72.254 IPING6 10.9.72.254 (10.9.72.254): 56 data bytes 64 bytes from 10.9.72.254: icmp_seq=0 ttl=121 time=2.9 ms --- 10.9.72.254 ping statistics --1 packets transmitted, 1 packets received, 0 percent packet loss round-trip min/avg/max = 2.9/2.9/2.9 ms This subcommand displays the comprehensive chassis status and configuration state information, and historic event logs. Used for postdeployment configuration verification and during debugging sessions. To use this subcommand for CMC, you must have the CMC Login User privilege. racadm racdump Racdump includes the following subsystems and aggregates the following RACADM commands: • General System/RAC information - getsysinfo 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

ping
Description
Verifies that the destination IP address is reachable from CMC with the
current routing-table contents. A destination IP address is required. An ICMP
echo packet is sent to the destination IP address based on the current
routing-table contents.
To use this subcommand for CMC, you must have the Administrator privilege
for CMC.
Synopsis
racadm ping <
ipaddress
>
ping6
Description
Verifies that the destination IPv6 address is reachable from an CMC, or with
the current routing-table contents. A destination IPv6 address is required. An
ICMP echo packet is sent to the destination IPv6 address on the basis of
current routing-table contents.
To use this subcommand for CMC, you must have the Administrator
privilege.
Synopsis
racadm ping6 <
ipv6address
>
Example
racadm iping6 10.9.72.254
IPING6 10.9.72.254 (10.9.72.254): 56 data bytes
64 bytes from 10.9.72.254: icmp_seq=0 ttl=121 time=2.9
ms
--- 10.9.72.254 ping statistics ---
1 packets transmitted, 1 packets received, 0 percent
packet loss
round-trip min/avg/max = 2.9/2.9/2.9 ms
racdump
Description
This subcommand displays the comprehensive chassis status and
configuration state information, and historic event logs. Used for post-
deployment configuration verification and during debugging sessions.
To use this subcommand for CMC, you must have the
CMC Login User
privilege.
Synopsis
racadm racdump
Input
Racdump
includes the following subsystems and aggregates the following
RACADM commands:
General System/RAC information -
getsysinfo
67