Dell PowerEdge FX2 Dell PowerEdge FX2 and FX2s Enclosure Owners Manual - Page 28

fanoffset, feature, Description, Chassis Configuration, Administrator, Synopsis, Input, Example

Page 28 highlights

fanoffset Description Synopsis Input Example feature Description Synopsis 28 • Configure the event generation interval and notifications for temperature statistics: racadm eventfilters set -c cmc.alert.system.tmps -r 5 n snmp Configures the internal fans to run at a higher speed than the normal speed. To use this subcommand, you must have the Chassis Configuration Administrator privilege. racadm fanoffset [-s Valid category values are: • off • low • medium • high s - Sets the fan speed. • Disable the fanoffset feature. racadm fanoffset -s off • Increases fan speed by 20% of fan's maximum speed. Minimum speed for fan is 35% of the maximum. racadm fanoffset -s low • Increases fan speed by 50% of fan's maximum speed. Minimum speed for fan is 65% of the maximum. racadm fanoffset -s medium • Sets fans to run at 100% of fan's maximum speed. racadm fanoffset -s high Displays all active chassis features. The information displayed includes feature name, date activated, and the serial number of the SD card used to activate the feature. Dell Feature Cards may contain more than one feature. NOTE: To use this subcommand to deactivate FlexAddress or ExtendedStorage, you must have the Chassis Configuration Administrator privilege. A user with login privileges can view status only. NOTE: To deactivate FlexAddress features, the chassis must be turned off. • racadm feature -s • racadm feature -d -c

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

Configure the event generation interval and notifications for temperature
statistics:
racadm eventfilters set -c cmc.alert.system.tmps -r 5 -
n snmp
fanoffset
Description
Configures the internal fans to run at a higher speed than the normal speed.
To use this subcommand, you must have the
Chassis Configuration
Administrator
privilege.
Synopsis
racadm fanoffset [-s <off|low|medium|high>
Valid category values are:
off
low
medium
high
Input
s
— Sets the fan speed.
Example
Disable the fanoffset feature.
racadm fanoffset -s off
Increases fan speed by 20% of fan’s maximum speed. Minimum speed for
fan is 35% of the maximum.
racadm fanoffset -s low
Increases fan speed by 50% of fan’s maximum speed. Minimum speed for
fan is 65% of the maximum.
racadm fanoffset -s medium
Sets fans to run at 100% of fan’s maximum speed.
racadm fanoffset -s high
feature
Description
Displays all active chassis features. The information displayed includes
feature name, date activated, and the serial number of the SD card used to
activate the feature.
Dell Feature Cards may contain more than one feature.
NOTE:
To use this subcommand to deactivate FlexAddress or
ExtendedStorage, you must have the
Chassis Configuration
Administrator
privilege. A user with login privileges can view status
only.
NOTE:
To deactivate FlexAddress features, the chassis must be turned
off.
Synopsis
racadm feature -s
racadm feature -d -c <
featurename
>
28