Dell PowerEdge FX2 Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0 - Page 198
Dell#Jan 3 14:27:00: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Con d from console
View all Dell PowerEdge FX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
CONFIGURATION mode boot system stack-unit unit-number primary system partition 3. Save the configuration. EXEC Privilege mode write memory 4. Reset the stack unit to activate the new Dell Networking OS version. EXEC Privilege mode power-cycle stack-unit unit-number Example of Upgrading a Single Stack Unit The following example shows how to upgrade an individual stack unit. Dell# upgrade system stack-unit 1 A Image upgraded to Stack unit 1 Dell# configure Dell(conf)# boot system stack-unit 1 primary system: A: Dell(conf)# end Dell#Jan 3 14:27:00: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console Dell# write memory Jan 3 14:27:10: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config in flash by default Synchronizing data to peer Stack-unit !!!! .... Dell# power-cycle stack-unit 1 Proceed with power-cycle? Confirm [yes/no]:yes 198 Stacking