Dell PowerEdge FX2 Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0 - Page 251

NPIV Proxy Gateway: Terms and Definitions, Fibre Channel fabric

Page 251 highlights

NPIV Proxy Gateway: Terms and Definitions The following table describes the terms used in an NPG configuration on the Aggregator. Table 20. Aggregator with the NPIV Proxy Gateway: Terms and Definitions Term FC port Description Fibre Channel port on the Aggregator that operates in autosensing, 2, 4, or 8-Gigabit mode. On an NPIV proxy gateway, an FC port can be used as a downlink for a server connection and an uplink for a fabric connection. F port Port mode of an FC port connected to an end node (N) port on an Aggregator with the NPIV proxy gateway. N port Port mode of an Aggregator with the FC port that connects to an F port on an FC switch in a SAN fabric. On an Aggregator with the NPIV proxy gateway, an N port also functions as a proxy for multiple server CNAport connections. ENode port Port mode of a server-facing Aggregator with the Ethernet port that provides access to FCF functionality on a fabric. CNA port N-port functionality on an FCoE-enabled server port. A converged network adapter (CNA) can use one or more Ethernet ports. CNAs can encapsulate Fibre Channel frames in Ethernet for FCoE transport and deencapsulate Fibre Channel frames from FCoE to native Fibre Channel. DCB map Template used to configure DCB parameters, including priority-based flow control (PFC) and enhanced transmission selection (ETS), on CEE ports. Fibre Channel fabric Network of Fibre Channel devices and storage arrays that inter-operate and communicate. FCF Fibre Channel forwarder: FCoE-enabled switch that can forward FC traffic to both downstream FCoE and upstream FC devices. An NPIV proxy gateway functions as an FCF to export upstream F port configurations to downstream server CNA ports. FC-MAP FCoE MAC-address prefix - The unique 24-bit MAC address prefix in FCoE packets used to generate a fabric-provided MAC address (FPMA). The FPMA is required to send FCoE packets from a server to a SAN fabric. FCoE map Template used to configure FCoE and FC parameters on Ethernet and FC ports in a converged fabric. FCoE VLAN VLAN dedicated to carrying only FCoE traffic between server CNA ports and a SAN fabric. (FCoE traffic must travel in a VLAN.) When you apply an FCoE map on a port, FCoE is enabled on the port. All non-FCoE traffic is dropped on an FCoE VLAN. FIP FCoE Initialization Protocol: Layer 2 protocol for endpoint discovery, fabric login, and fabric association. FIP is used by server CNAs to discover NPIV Proxy Gateway 251

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292

NPIV Proxy Gateway: Terms and Definitions
The following table describes the terms used in an NPG configuration on the Aggregator.
Table 20. Aggregator with the NPIV Proxy Gateway: Terms and Definitions
Term
Description
FC port
Fibre Channel port on the Aggregator that operates in autosensing, 2, 4,
or 8-Gigabit mode. On an NPIV proxy gateway, an FC port can be used
as a downlink for a server connection and an uplink for a fabric
connection.
F port
Port mode of an FC port connected to an end node (N) port on an
Aggregator with the NPIV proxy gateway.
N port
Port mode of an Aggregator with the FC port that connects to an F port
on an FC switch in a SAN fabric. On an Aggregator with the NPIV proxy
gateway, an N port also functions as a proxy for multiple server CNA-
port connections.
ENode port
Port mode of a server-facing Aggregator with the Ethernet port that
provides access to FCF functionality on a fabric.
CNA port
N-port functionality on an FCoE-enabled server port. A converged
network adapter (CNA) can use one or more Ethernet ports. CNAs can
encapsulate Fibre Channel frames in Ethernet for FCoE transport and de-
encapsulate Fibre Channel frames from FCoE to native Fibre Channel.
DCB map
Template used to configure DCB parameters, including priority-based
flow control (PFC) and enhanced transmission selection (ETS), on CEE
ports.
Fibre Channel fabric
Network of Fibre Channel devices and storage arrays that inter-operate
and communicate.
FCF
Fibre Channel forwarder: FCoE-enabled switch that can forward FC
traffic to both downstream FCoE and upstream FC devices. An NPIV
proxy gateway functions as an FCF to export upstream F port
configurations to downstream server CNA ports.
FC-MAP
FCoE MAC-address prefix — The unique 24-bit MAC address prefix in
FCoE packets used to generate a fabric-provided MAC address (FPMA).
The FPMA is required to send FCoE packets from a server to a SAN fabric.
FCoE map
Template used to configure FCoE and FC parameters on Ethernet and
FC ports in a converged fabric.
FCoE VLAN
VLAN dedicated to carrying only FCoE traffic between server CNA ports
and a SAN fabric. (FCoE traffic must travel in a VLAN.) When you apply an
FCoE map on a port, FCoE is enabled on the port. All non-FCoE traffic is
dropped on an FCoE VLAN.
FIP
FCoE Initialization Protocol: Layer 2 protocol for endpoint discovery,
fabric login, and fabric association. FIP is used by server CNAs to discover
NPIV Proxy Gateway