Dell PowerEdge MX7000 EMC OpenManage Enterprise-Modular Edition Version 1.00.1 - Page 24

Group Deployment Wizard, Power loss owing to any chassis in the stack.

Page 24 highlights

• Ensure that the chassis settings are selected for applying to the other chassis-Power, user authentication, alert destination, time, proxy, security, network services, local access. Before creating an MCM group, ensure that the MX7000 management networks are wired together in a stacked configuration. The stacked configuration helps in surviving: • A single network cable failure. • A single management module failure. • Power loss owing to any chassis in the stack. • Failover of a chassis in the stack. NOTE: If any of the issues that are listed above occur, the management network access to all components in the daisy-chained group may be interrupted for up to 10 minutes. The OME - Modular web interface recovers automatically. The wired chassis are displayed as under "Available Chassis" in the Group Deployment Wizard. The following image is an illustration of the recommended MCM wiring: 24 Logging in to OME-Modular

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Ensure that the chassis settings are selected for applying to the other chassis—Power, user authentication, alert destination, time,
proxy, security, network services, local access.
Before creating an MCM group, ensure that the MX7000 management networks are wired together in a stacked
configuration.
The
stacked
configuration
helps in surviving:
A single network cable failure.
A single management module failure.
Power loss owing to any chassis in the stack.
Failover of a chassis in the stack.
NOTE:
If any of the issues that are listed above occur, the management network access to all components in the daisy-chained
group may be interrupted for up to 10 minutes. The OME - Modular web interface recovers automatically.
The wired chassis are displayed as under "Available Chassis" in the
Group Deployment Wizard
.
The following image is an illustration of the recommended MCM wiring:
24
Logging in to OME-Modular