Recommended physical topology
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Recommended physical topology The recommended minimum design for a scalable fabric is two chassis with fabric A populated with redundant IOMs. Ideally, the two chassis are located in separate racks on separate power circuits to provide the highest redundancy. Additional chassis only have FEMs and the appear as the image below. Table 4. Fabric topology Chassis Slot Chassis 1 A1 A2 Chassis 2 A1 A2 Chassis 3-10 A1 A2 You can also use Fabric B to create a second scalable fabric: Module MX9116n FSE MX7116n FEM MX7116n FEM MX9116n FSE MX7116n FEM MX7116n FEM MX scalable fabric architecture 63
Recommended physical topology
The recommended minimum design for a scalable fabric is two chassis with fabric A populated with redundant IOMs. Ideally, the two
chassis are located in separate racks on separate power circuits to provide the highest redundancy.
Additional chassis only have FEMs and the appear as the image below.