Dell PowerEdge R210 II Owner's Manual - Page 21
Link Width is, Actual Link
View all Dell PowerEdge R210 II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Message Causes Corrective Actions PCIe Training Error: Expected Link Width is x, Actual Link Width is y. Faulty or improperly installed PCIe card in the specified slot. Reseat the PCIe card in the specified slot number. See "Troubleshooting an Expansion Card" on page 109. If the problem persists, see "Getting Help" on page 119. SATA Portx device not found. SATA port x device autosensing error. There is no device connected Information only. to the specified SATA port. The drive connected to the Replace the faulty drive. specified SATA port is faulty. SATA port x device configuration error. SATA port x device error. The amount of system memory has changed. Memory has been added or removed or a memory module may be faulty. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program. battery. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 104. Check the Time and Date settings. See "Using the System Setup Program and Boot Manager" on page 25. If the problem persists, replace the system battery. See "System Battery" on page 89. About Your System 21