Dell PowerVault MD3260i CLI Guide - Page 14

Command Line Parameters, SMcli -m, SMcli -X -n, name-or-IP-address, address

Page 14 highlights

[-n storage-array-name | -w WWID | -h host-name | -r (host_sa | direct_sa)] [-S] SMcli -d [-w][-i][-s][-v][-S] SMcli -m host-name-or-IP-address -F email-address [-g contactInfoFile][-S] SMcli -A [host-name-or-IP-address [host-name-or-IP-address]] [-S] SMcli -X (-n storage-array-name | -w WWID | -h host-name) SMcli -? Command Line Parameters Table 2. Command Line Parameters Parameter host‑name-or-IP-address -A -a Definition Specify either the host name or the Internet Protocol (IP) address of an in-band managed storage array (IPv4 or IPv6) or an out-of-band managed storage array (IPv4 or IPv6). • If you manage a storage array by using a host cstoonrnaegcetmedandairgeecmtlyetnot)t,hyeoustmoruasgteuaserrathye(i-nn‑band parameter if more than one storage array is connected to the host. • If you manage a storage array through an Ethernet connection (out-of-band storage management), you must specify the harorasyto‑nf ainmdeep‑oernd‑IenPt‑adidsdksr(eRsAsIDo)fctohnetrreodlleurndant modules. • If you have previously configured a storage array in the graphical user interface (GUI) of the MD Storage Manager, you can specify the storage array by its parameter. user‑supplied name by using the -n Use to add a storage array to the configuration files. If you do not follow the -A parameter with a host‑name‑or‑IP‑address, automatic discovery scans the local subnet for storage arrays. Use to add an SNMP trap destination or an e-mail address alert destination. • When adding an SNMP trap destination, the SNMP community is automatically defined as the community name for the trap and the host is the IP address or Domain Name Server (DNS) host name of the system to which the trap should be sent. • When adding an e-mail address for an alert destination, the email-address is the e-mail address to which to send the alert message. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

[-n
storage-array-name
| -w
WWID
| -h
host-name
|
-r (
host_sa
|
direct_sa
)] [-S]
SMcli -d [-w][-i][-s][-v][-S]
SMcli -m
host-name-or-IP-address
-F
email-address
[-g
contactInfoFile
][-S]
SMcli -A [
host-name-or-IP-address
[
host-name-or-IP-address
]] [-S]
SMcli -X (-n
storage-array-name
| -w
WWID
|
-h
host-name
)
SMcli -?
Command Line Parameters
Table 2. Command Line Parameters
Parameter
Definition
host
name-or-IP-address
Specify either the host name or the Internet Protocol (IP)
address of an in-band managed storage array (IPv4 or
IPv6) or an out-of-band managed storage array (IPv4 or
IPv6).
If you manage a storage array by using a host
connected directly to the storage array (in
band
storage management), you must use the
-n
parameter if more than one storage array is
connected to the host.
If you manage a storage array through an Ethernet
connection (out-of-band storage management),
you must specify the
host
name
or
IP
address
of the redundant
array of independent disks (RAID) controller
modules.
If you have previously configured a storage array
in the graphical user interface (GUI) of the MD
Storage Manager, you can specify the storage
array by its user
supplied name by using the
-n
parameter.
-A
Use to add a storage array to the configuration files. If you
do not follow the
-A
parameter with a
host
name
or
IP
address
, automatic discovery
scans the local subnet for storage arrays.
-a
Use to add an SNMP trap destination or an e-mail address
alert destination.
When adding an SNMP trap destination, the
SNMP community is automatically defined as the
community name for the trap and the
host
is the IP
address or Domain Name Server (DNS) host name
of the system to which the trap should be sent.
When adding an e-mail address for an alert
destination, the
email-address
is the e-mail
address to which to send the alert message.
14