Dell PowerVault MD3260i CLI Guide - Page 159

Save Storage Array Configuration, hostTopology=TRUE | FALSE

Page 159 highlights

Parameters Parameter controller file Description RAID controller module with the NVSRAM values to save. Valid RAID controller module identifier values are 0 and 1. The identifier value is 0 for the RAID controller module on the top and 1 for the RAID controller module on the bottom when viewed from the rear of the enclosure. You must put brackets ([ ]) around the RAID controller module identifier. Name of the file in which to save the values. You must put quotation marks (" ") around the file name. Save Storage Array Configuration This command creates a script file that you can use to create the current storage array virtual disk configuration. Syntax save storageArray configuration file="filename" [(allConfig | globalSettings=(TRUE | FALSE) virtualDiskConfigAndSettings=(TRUE | FALSE) hostTopology=(TRUE | FALSE) lunMappings=(TRUE | FALSE))] Parameters Parameter Description file Name of the file that contains the configuration values. You must put quotation marks (" ") around the file name. allConfig Saves all of the configuration values to the file. (If you choose this parameter, all of the configuration parameters are set to TRUE.) globalSettings Saves the global settings to the file. To save the global settings, set this parameter to TRUE. To prevent saving the global settings, set this parameter to FALSE. The default value is TRUE. virtualDiskConfigAndSettings Saves the virtual disk configuration settings and all of the global settings to the file. To save the virtual disk configuration and global settings, set this parameter to TRUE. To prevent saving the virtual disk configuration and global settings, set this parameter to FALSE. The default value is TRUE. hostTopology Saves the host topology to the file. To save the host topology, set this parameter to TRUE. To prevent saving the host topology, set this parameter to FALSE. The default value is FALSE. lunMappings Saves the LUN mapping to the file. To save the LUN mapping, set this parameter to TRUE. To prevent saving 159

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

Parameters
Parameter
Description
controller
RAID controller module with the NVSRAM values to save.
Valid RAID controller module identifier values are
0
and
1
.
The identifier value is
0
for the RAID controller module on
the top and
1
for the RAID controller module on the
bottom when viewed from the rear of the enclosure. You
must put brackets ([ ]) around the RAID controller module
identifier.
file
Name of the file in which to save the values. You must put
quotation marks (" ") around the file name.
Save Storage Array Configuration
This command creates a script file that you can use to create the current storage array virtual disk configuration.
Syntax
save storageArray configuration file="
filename
"
[(allConfig | globalSettings=(TRUE | FALSE) virtualDiskConfigAndSettings=(TRUE
| FALSE)
hostTopology=(TRUE | FALSE)
lunMappings=(TRUE | FALSE))]
Parameters
Parameter
Description
file
Name of the file that contains the configuration values.
You must put quotation marks (" ") around the file name.
allConfig
Saves all of the configuration values to the file. (If you
choose this parameter, all of the configuration parameters
are set to
TRUE
.)
globalSettings
Saves the global settings to the file. To save the global
settings, set this parameter to
TRUE
. To prevent saving
the global settings, set this parameter to
FALSE
. The
default value is
TRUE
.
virtualDiskConfigAndSettings
Saves the virtual disk configuration settings and all of the
global settings to the file. To save the virtual disk
configuration and global settings, set this parameter to
TRUE
. To prevent saving the virtual disk configuration and
global settings, set this parameter to
FALSE
. The default
value is
TRUE
.
hostTopology
Saves the host topology to the file. To save the host
topology, set this parameter to
TRUE
. To prevent saving
the host topology, set this parameter to
FALSE
. The
default value is
FALSE
.
lunMappings
Saves the LUN mapping to the file. To save the LUN
mapping, set this parameter to
TRUE
. To prevent saving
159