TM-L90 Peeler Model unrecoverable errors

Page 117 highlights

TM-L90/TM-L90 Peeler Model Technical Reference Guide ❏ TM-L90 Peeler Model unrecoverable errors Unrecoverable Errors Error name Type of error Error LED flash code Approx.320 ms Recovery measure R/W error in memory After R/W checking, the printer does not work correctly. LED ON LED OFF High voltage error Low voltage error CPU execution error Internal circuit connection error The power supply voltage is extremely high. LED ON LED OFF The power supply voltage is extremely low. LED ON LED OFF The CPU executes an incorrect address or I/F board is not connected. Internal circuits are not connected correctly. LED ON LED OFF LED ON LED OFF UIB error An abnormal operation occurs in UIB. LED ON LED OFF Approx.5120 ms Approx.2560 ms Impossible to recover. Impossible to recover. Impossible to recover. Impossible to recover. Impossible to recover. Impossible to recover. Handling 117

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Handling
117
TM-L90/TM-L90 Peeler Model Technical Reference Guide
TM-L90 Peeler Model unrecoverable errors
Unrecoverable Errors
Error name
Type of error
Error LED flash code
Recovery measure
R/W error in memory
After R/W checking, the
printer does not work
correctly.
Impossible to
recover.
High voltage error
The power supply voltage
is extremely high.
Impossible to
recover.
Low voltage error
The power supply voltage
is extremely low.
Impossible to
recover.
CPU execution error
The CPU executes an
incorrect address or I/F
board is not connected.
Impossible to
recover.
Internal circuit
connection error
Internal circuits are not
connected correctly.
Impossible to
recover.
UIB error
An abnormal operation
occurs in UIB.
Impossible to
recover.
Approx.
3
20 m
s
Approx.5120 m
s
LED ON
LED OFF
LED ON
LED OFF
LED ON
LED OFF
LED ON
LED OFF
Approx.2560 m
s
LED ON
LED OFF
LED ON
LED OFF