HP 303B Maintenance & Service Guide: HP 303B Microtower Business PC - Page 85
Specifications, Table H-1
View all HP 303B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
H Specifications Table H-1 Specifications Temperature Range Operating Nonoperating 50° to 95°F -22° to 140°F 10° to 35°C -30° to 60°C Relative Humidity (noncondensing) Operating Nonoperating (38.7°C max wet bulb) 10-90% 10-90% 10-90% 10-90% Maximum Altitude (unpressurized) Operating Nonoperating 10,000 ft 30,000 ft 3048 m 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Shock The level of shock the product can withstand with no damage being incurred is 35 G peak input acceleration during an 11-millisecond trapezoidal shock pulse. Vibration Operating Non-operating 5 Hz to 300 Hz (0.25 G nominal 5 Hz to 500 Hz (2 G nominal) NOTE: Listed are the levels of vibration the product can withstand with no damage being incurred. The values represent a flat random vibration input acceleration profile across the given frequency range. Acoustic noise Idle, fixed disk drive spinning DVD-ROM sequential reads LWAd = 43 dB LWAd = 55 dB Desktop average LpAm = 32 dBA Deskside average LpAm = 44 dBA NOTE: Listed are the declared A-weighted sound power levels (LWAd) and declared average desktop seated operator position A-weighted sound pressure levels (LpAm) when the product is operating in a 23°C (73.4°F) ambient environment. NOTE: Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). 77