HP Surestore Tape Library Model 20/700 HP Surestore Bridge FC 2/1 LV and FC 4/ - Page 137

Main Menu > Configuration > FC to SCSI Mapping, Enter loop, address of AL_PA, Mode Selection

Page 137 highlights

Chapter 6 Figure 44 Select an AL_PA value from the table and enter it into the field Enter loop address of AL_PA at the bottom of the screen. For more information, see Appendix C. Main Menu > Configuration > FC to SCSI Mapping This menu allows for setting the Fibre Channel Address method, Hard Address value, discovery mode, WWN overrides and FC Port mode. FC to SCSI Mapping Page ■ Mode Selection determines the mode of Fibre Channel to SCSI Mapping. The following options are available: SCC Indexed Auto-assigned, LUN priority Auto-assigned, target ID priority Auto-assigned, bus number priority SCC mode is used to address SCSI devices attached to the bridge using the SCSI-3 Controller Commands method of logical unit addressing. In this mode, the bridge will respond to FCP commands as in a SCC controller device. The FC HBA must support this addressing method. Chapter 6 Main Menu 139

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

Chapter 6
Main Menu
139
Chapter 6
Select an AL_PA value from the table and enter it into the field
Enter loop
address of AL_PA
at the bottom of the screen.
For more information, see
Appendix C
.
Main Menu > Configuration > FC to SCSI Mapping
This menu allows for setting the Fibre Channel Address method, Hard Address
value, discovery mode, WWN overrides and FC Port mode.
Figure 44
FC to SCSI Mapping Page
Mode Selection
determines the mode of Fibre Channel to SCSI Mapping.
The following options are available:
SCC
Indexed
Auto-assigned, LUN priority
Auto-assigned, target ID priority
Auto-assigned, bus number priority
SCC mode
is used to address SCSI devices attached to the bridge using
the SCSI-3 Controller Commands method of logical unit addressing. In this
mode, the bridge will respond to FCP commands as in a SCC controller
device. The FC HBA must support this addressing method.