HP Surestore Tape Library Model 20/700 HP Surestore Bridge FC 2/1 LV and FC 4/ - Page 212

Virtual Inquiry Command, A4688A FC 4/1 HV

Page 212 highlights

Table 13 LUN Inquiry Data Item RelAdr Wbus32 Wbus16 Sync Linked CmdQue SftRe Vendor Product ID Revision Level Value 0x00 0x00 0x00 0x00 0x00 0x00 0x00 HP A4688A (FC 4/1 HV) A4689A (FC 2/1 LV) "XXXX" The bridge will only reply to a SCSI Inquiry when using 8-byte LUN field of 0x00's. Once the bridge has been detected, then the devices on the SCSI-2 can be detected using the SCC Logical unit addressing. Note The Revision Level comes from the last four characters of the build string, which appears in the headings for most menu screens. Virtual Inquiry Command Modeled after the INQUIRY Command, this command passes through an inquiry command to the device with the specified FCP-LUN. In addition to the INQUIRY Data from the device, 10 extra bytes of vendor unique data is appended onto the end of the device's data and returned, along with the device's data, to the initiator. 214 In-Band Management Appendix B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

214
In-Band Management
Appendix B
The bridge will only reply to a SCSI Inquiry when using 8-byte LUN field of
0x00's. Once the bridge has been detected, then the devices on the SCSI-2
can be detected using the SCC Logical unit addressing.
Note
The Revision Level comes from the last four characters of the
build string, which appears in the headings for most menu
screens.
Virtual Inquiry Command
Modeled after the INQUIRY Command, this command passes through an
inquiry command to the device with the specified FCP-LUN. In addition to the
INQUIRY Data from the device, 10 extra bytes of vendor unique data is
appended onto the end of the device's data and returned, along with the
device's data, to the initiator.
RelAdr
0x00
Wbus32
0x00
Wbus16
0x00
Sync
0x00
Linked
0x00
CmdQue
0x00
SftRe
0x00
Vendor
HP
Product ID
A4688A (FC 4/1 HV)
A4689A (FC 2/1 LV)
Revision Level
"XXXX"
Table 13
LUN Inquiry Data
Item
Value