IBM 88614RX Maintenance Manual - Page 105

Diagnostic error codes, See System Error log.

Page 105 highlights

Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Light path LED FRU/action LOG (non-optimal condition) 1. See System Error log. 2. See Service Processor log. OVER SPEC (power supplies are being overdriven) 1. Power supply 2. Power backplane Diagnostic error codes Note: In the following error codes, if xxx is 000, 195, or 197, do not replace a FRU. The description for these error codes are: 000 The server passed the test. 195 The Esc key was pressed to end the test. 197 This is a warning error and might not indicate a hardware failure. For all error codes, replace the FRU or follow the action indicated. Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Error code/symptom FRU/action 001-198-000 (Test Aborted) 1. Check error log for messages. 2. Run Quick Memory Test All Banks. 3. Reload server BIOS code and rerun test. 001-250-00x (Test Failed) x of 0 = ECC logic on I/O board; x of 1 = ECC logic on memory board 1. Check error log for messages. 2. Run Quick Memory Test All Banks. 3. Rerun ECC test. 4. Memory cassette. 5. I/O board. 001-292-000 (Core system: failed/CMOS checksum failed) Load BIOS defaults and rerun test. 001-xxx-000 (Failed core tests) v I/O board 001-xxx-001 (Failed core tests) v I/O board 005-xxx-000 (Failed Video test) v I/O board 011-xxx-000 (Failed COM1 Serial Port test) v I/O board 015-xxx-001 (Failed USB test) v I/O board 015-xxx-015 (Failed USB external loopback test) v I/O board 015-xxx-198 (Remote Supervisor Adapter II installed) or (USB device connected during USB test) 1. If Remote Supervisor Adapter II is installed as an option, remove it and rerun test. Note: If Remote Supervisor Adapter II is present as a standard installation, do not remove it; the test cannot be run. 2. Remove USB devices and rerun test. 3. I/O board. Chapter 6. Symptom-to-FRU index 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Light path LED
FRU/action
LOG
(non-optimal condition)
1.
See System Error log.
2.
See Service Processor log.
OVER SPEC
(power supplies are
being overdriven)
1.
Power supply
2.
Power backplane
Diagnostic error codes
Note:
In the following error codes, if xxx is 000, 195, or 197,
do not
replace a FRU.
The description for these error codes are:
000
The server passed the test.
195
The Esc key was pressed to end the test.
197
This is a warning error and might not indicate a hardware failure.
For all error codes, replace the FRU or follow the action indicated.
Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
FRU/action
001-198-000
(Test Aborted)
1.
Check error log for messages.
2.
Run Quick Memory Test All Banks.
3.
Reload server BIOS code and rerun test.
001-250-00x
(Test Failed)
x of 0 = ECC logic on I/O board; x of 1 =
ECC logic on memory board
1.
Check error log for messages.
2.
Run Quick Memory Test All Banks.
3.
Rerun ECC test.
4.
Memory cassette.
5.
I/O board.
001-292-000
(Core system: failed/CMOS
checksum failed)
Load BIOS defaults and rerun test.
001-xxx-000
(Failed core tests)
v
I/O board
001-xxx-001
(Failed core tests)
v
I/O board
005-xxx-000
(Failed Video test)
v
I/O board
011-xxx-000
(Failed COM1 Serial Port
test)
v
I/O board
015-xxx-001
(Failed USB test)
v
I/O board
015-xxx-015
(Failed USB external
loopback test)
v
I/O board
015-xxx-198
(Remote Supervisor Adapter
II installed)
or
(USB device connected
during USB test)
1.
If Remote Supervisor Adapter II is installed as an option,
remove it and rerun test.
Note:
If Remote Supervisor Adapter II is present as a standard
installation, do not remove it; the test cannot be run.
2.
Remove USB devices and rerun test.
3.
I/O board.
Chapter 6. Symptom-to-FRU index
95