IBM 88614RX Maintenance Manual - Page 110
Expansion Enclosure., Hardware Maintenance Manual
UPC - 000435172662
View all IBM 88614RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Error code/symptom FRU/action 166-201-114 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 2) Expansion Enclosure. 166-201-115 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 3) Expansion Enclosure. 166-201-116 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 4) Expansion Enclosure. 166-201-117 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 5) Expansion Enclosure. 166-201-118 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 6) Expansion Enclosure. 166-260-000 (ASM restart failure) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 2. Remote Supervisor Adapter. 166-342-000 (System Management BIST indicates failed tests) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 2. Remote Supervisor Adapter. 166-400-000 (ISMP Self Test Result failed 1. Disconnect all server and option power cords from server, wait tests: xxx) where xxx=flash, ROM, or RAM 30 seconds, reconnect, and retry. 2. (Re)flash ISMP with latest firmware level. 3. I/O board. 166-400-100 (DMC Self Test Result failed 1. Disconnect all server and option power cords from server, wait tests: xxx) where xxx=flash, ROM, or RAM 30 seconds, reconnect, and retry. 2. (Re)flash ISMP on RXE with latest firmware level. 3. RXE backplane. 180-197-000 (SCSI ASPI driver not installed) 1. Remove RAID adapter, if installed, and rerun test. 2. SCSI backplane. 3. I/O board. 4. Microprocessor tray assembly. 180-361-003 (Failed Fan LED test) 1. Fan 2. I/O board 180-xxx-000 (Diagnostics LED failure) v Run diagnostic LED test for failing LED. 180-xxx-001 (Failed Front LED Panel test) 1. Operator information panel cable 2. Operator information panel 3. I/O board 4. Microprocessor tray assembly 180-xxx-002 (Failed Diagnostics LED Panel test) 1. Operator information panel cable 2. Operator information panel 3. I/O board 4. Microprocessor tray assembly 100 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide