IBM 88614RX Maintenance Manual - Page 107

SCSI disk with ID nn on adapter in slot s, Power supply

Page 107 highlights

Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Error code/symptom FRU/action 035-xxx-cnn (Check System error Log before replacing a FRU. c = ServeRAID channel number, nn = SCSI ID of failing fixed disk drive.) v Hard disk drive on channel C, SCSI ID nn 035-xxx-snn (Check System Error Log before replacing a FRU. nn = SCSI ID of failing fixed disk.) v SCSI disk with ID nn on adapter in slot s 075-xxx-000 (Failed power supply test) 1. Power supply 2. Power backplane 089-xxx-001 (Failed Microprocessor test) 1. Microprocessor 1 2. Microprocessor tray assembly 089-xxx-002 (Failed Optional Microprocessor test) 1. Microprocessor 2 2. Microprocessor tray assembly 089-xxx-003 (Failed Microprocessor test) 1. Microprocessor 3 2. VRM 3 3. Microprocessor tray assembly 089-xxx-004 (Failed Microprocessor test) 1. Microprocessor 4 2. VRM 4 3. Microprocessor tray assembly 091-09x-041 (RXE Expansion Port failure; 1. RXE cable valid only with RXE cable) (where x of 4 = cable or initialization error; x of 5 = 2. I/O board transmit error; x of 6 = receive error; x of 7 = ping error, below threshold) 091-09x-056 (RXE100 Side A Port failure) 1. RXE cable (where x of 4 = cable or initialization error; x of 5 = transmit error; x of 6 = receive error; x of 7 = ping error, below threshold) 2. RXE Expansion board to which cable is connected (Side A or Side B) 3. I/O board 091-09x-057 (RXE100, from Side A to 1. Side A card in RXE100 Side B failure) (where x of 4 = cable or initialization error; x of 5 = transmit error; x 2. Side B card in RXE100 of 6 = receive error; x of 7 = ping error, below threshold) 091-09x-058 (RXE100 Side B Port failure) 1. RXE cable (where x of 4 = cable or initialization error; x of 5 = transmit error; x of 6 = receive error; x of 7 = ping error, below threshold) 2. RXE Expansion board to which cable is connected (Side A or Side B) 3. I/O board 091-09x-059 (RXE100, from Side B to 1. Side B card in RXE100 Side A failure) (where x of 4 = cable or initialization error; x of 5 = transmit error; x 2. Side A card in RXE100 of 6 = receive error; x of 7 = ping error, below threshold) 155-xxx-xxx (Failed Active Memory™ latch 1. Memory cassette cover assembly test) 2. Memory cassette Chapter 6. Symptom-to-FRU index 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
FRU/action
035-xxx-cnn
(Check System error Log
before replacing a FRU. c = ServeRAID
channel number, nn = SCSI ID of failing
fixed disk drive.)
v
Hard disk drive on channel C, SCSI ID nn
035-xxx-snn
(Check System Error Log
before replacing a FRU. nn = SCSI ID of
failing fixed disk.)
v
SCSI disk with ID nn on adapter in slot s
075-xxx-000
(Failed power supply test)
1.
Power supply
2.
Power backplane
089-xxx-001
(Failed Microprocessor test)
1.
Microprocessor 1
2.
Microprocessor tray assembly
089-xxx-002
(Failed Optional
Microprocessor test)
1.
Microprocessor 2
2.
Microprocessor tray assembly
089-xxx-003
(Failed Microprocessor test)
1.
Microprocessor 3
2.
VRM 3
3.
Microprocessor tray assembly
089-xxx-004
(Failed Microprocessor test)
1.
Microprocessor 4
2.
VRM 4
3.
Microprocessor tray assembly
091-09x-041
(RXE Expansion Port failure;
valid only with RXE cable) (where x of 4 =
cable or initialization error; x of 5 =
transmit error; x of 6 = receive error; x of 7
= ping error, below threshold)
1.
RXE cable
2.
I/O board
091-09x-056
(RXE100 Side A Port failure)
(where x of 4 = cable or initialization error;
x of 5 = transmit error; x of 6 = receive
error; x of 7 = ping error, below threshold)
1.
RXE cable
2.
RXE Expansion board to which cable is connected (Side A or Side
B)
3.
I/O board
091-09x-057
(RXE100, from Side A to
Side B failure) (where x of 4 = cable or
initialization error; x of 5 = transmit error; x
of 6 = receive error; x of 7 = ping error,
below threshold)
1.
Side A card in RXE100
2.
Side B card in RXE100
091-09x-058
(RXE100 Side B Port failure)
(where x of 4 = cable or initialization error;
x of 5 = transmit error; x of 6 = receive
error; x of 7 = ping error, below threshold)
1.
RXE cable
2.
RXE Expansion board to which cable is connected (Side A or Side
B)
3.
I/O board
091-09x-059
(RXE100, from Side B to
Side A failure) (where x of 4 = cable or
initialization error; x of 5 = transmit error; x
of 6 = receive error; x of 7 = ping error,
below threshold)
1.
Side B card in RXE100
2.
Side A card in RXE100
155-xxx-xxx
(Failed Active Memory
latch
test)
1.
Memory cassette cover assembly
2.
Memory cassette
Chapter 6. Symptom-to-FRU index
97