Intel SC5400RA User Guide - Page 49

Installing the Front Bezel (Pedestal Only), Installing the Front Bezel

Page 49 highlights

Installing the Front Bezel (Pedestal Only) Caution: This step applies to a pedestal configuration system only. For instructions on installing a bezel in a rack-mount configuration, see the Rack Conversion kit Installation Guide: Intel® Server Chassis SC5400. 1. Open the outer bezel door of the bezel assembly (see letter "A" in the following figure). 2. Remove the filler panels that correspond to installed devices (see letter "B"). 3. Close the outer bezel door (see letter "C"). 4. Fit the right edge of the bezel assembly against the right side of the chassis. 5. Engage the plastic bezel hooks (see letter "D") into the raised metal slots at the chassis edge. 6. Rotate the bezel assembly toward the chassis. 7. Latch the two plastic tabs (see letter "E") on the left side of the bezel assembly to the chassis. D B E A C E Figure 15. Installing the Front Bezel 40° Max AF001505 Intel® Server System SC5400RA User's Guide 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

Intel® Server System SC5400RA User’s Guide
27
Installing the Front Bezel (Pedestal Only)
Caution:
This step applies to a pedestal configuration system only. For instructions on installing a
bezel in a rack-mount configuration, see the Rack Conversion kit Installation Guide:
Intel
®
Server Chassis SC5400.
1.
Open the outer bezel door of the bezel assembly (see letter “A” in the following
figure).
2.
Remove the filler panels that correspond to installed devices (see letter “B”).
3.
Close the outer bezel door (see letter “C”).
4.
Fit the right edge of the bezel assembly against the right side of the chassis.
5.
Engage the plastic bezel hooks (see letter “D”) into the raised metal slots at the
chassis edge.
6.
Rotate the bezel assembly toward the chassis.
7.
Latch the two plastic tabs (see letter “E”) on the left side of the bezel assembly to
the chassis.
Figure 15. Installing the Front Bezel
AF001505
40
°
Max
B
A
C
E
D
E