bizhub 160/160f bizhub 161/161f 16. Soft Switch Set (bizhub 160f/bizhub 161f only) 16.8.2 SOFT SWITCH: #02 Field Service Ver. 1.0 Apr. 2005 Bit Designation No. Function 8 Time between phase C RX Insensitivity 70 ms 120 ms 180 ms 60 ms 7 to phase D signal in V.17 Bit 8 0 0 1 1 Bit 7 0 1 0 1 Example: Image --> EOP 6 Header TX selection 0: No open to user 1: Yes 5 Reserved Reserved 4 Reserved Reserved 3 Transmit RTN signal 2 level criteria Percentage of error line Bit 3 Bit 2 10 % 0 0 15 % 0 1 20 % 1 0 25 % 1 1 Initial Setting Bit HEX 02 0 1 0 00 0 0 1 Sent N.G page 0: Send N.G page and up to 3 times for that page 0 1: Not re-send that N.G page for G3 mode • Bit 1 :If this bit is set to '0', N.G indicates our side detected RTN signal from other end. In this case machine can re-send the same page up to three or just one time, and this use for G3 mode only. • Bit 2 to 3 :In G3 mode, if error line for each page meets the criteria setting, receiving machine will send RTN signal, in this case, some machine will re-send the same page again. The retry times depend on transmission side. • Bit 6 :If this bit is set to '0', the header select function can not be changed by user, only changeable by serviceman in service mode. Adjustment / Setting 184