Konica Minolta bizhub 160 Service Manual - Page 268
Field Service Ver. 1.0 Apr. 2005, Fax Protocols
View all Konica Minolta bizhub 160 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 268 highlights
bizhub 160/160f bizhub 161/161f Field Service Ver. 1.0 Apr. 2005 17. Fax Protocols Bit No. Designation DIS/DTC DCS 27 "0"= Invalid "1"= ECM 28 Set to "0" Frame size 0: 256 octets Frame size 1: 64 octets 29 Set to "0" 30 Set to "0" 31 "0"= Invalid "1"= T.6 coding capability "0"= Invalid "1"= T.6 coding enabled 32 Extend field "0"= Without "1"= With 33 "0"= Invalid "1"= Field not valid capability 34 "0"= Invalid "1"= Multiple selective polling capability Set to "0" "0"= Invalid 35 "1"= Polling subaddress transmission (DTC) by Polled Sub- Set to "0" Address (DIS)/PSA 36 "0"= Invalid "1"= T.43 coding 37 "0"= Invalid "1"= Plane interleave 38 Set to "0" 39 Set to "0" 40 Extend field "0"= Without "1"= With 41 "0"= Invalid "1"= R8 x 15.4 lines/mm 42 "0"= Invalid "1"= 300 x 300 pels/25.4 mm 43 "0"= Invalid "1"= R16 x 15.4 lines/mm and/or 400 x 400 pels/25.4 mm 44 "0"= Invalid "1"= Inch based resolution preferred Resolution type selection "0"= metric based resolution "1"= inch based resolution 45 "0"= Invalid "1"= Metric based resolution preferred Do not care 46 Minimum scan line time capability for higher resolutions. "0": T 15.4 = T 7.7 "1": T 15.4 = 1/2 T 7.7 Do not care "0"= Invalid 47 "1"= Selective polling (DIS)/ Selective polling transmission Set to "0" (DTC) 48 Extend field 0: Without 1: With 49 "0"= Invalid "1"= Sub Addressing capability "0"= Invalid "1"= Sub Addressing transmission Adjustment / Setting 235