bizhub 160/160f bizhub 161/161f 16. Soft Switch Set (bizhub 160f/bizhub 161f only) 16.8.11 SOFT SWITCH: #11 Field Service Ver. 1.0 Apr. 2005 Bit Designation No. Function 8 Reserved Reserved 7 Detect dial tone after 0: No pre-fix number 1: Yes 6 Pulse dial allowed to 0: Yes select 1: Not allowed 5 Reserved Reserved 4 Reserved Reserved 3 Reserved Reserved 2 Reserved Reserved 1 DTMF high frequency dB value 0: Base on SW19 (1 to 4) 1: High 1dB Initial Setting Bit HEX 0 0 0 0 0 0 0 0 0 0 • Bit 6: If this bit is set to 1, not allowed user to select Pulse dial, and this function open for serviceman to change. • Bit 7: Bit set to 1, LCD will show the command between each party. 16.8.12 SOFT SWITCH: #12 Bit Designation No. Function 8 ECM mode capabil- 1: Yes ity 0: No - also disable V.34 modem capability 7 V.34 fall back level 6 for V.34 TX. Counter Bit 7 1 0 Bit 6 0 2 3 0 1 1 0 5 Send CTC after 4th 0: Send CTC (Continue To Correct) PPR 1: Send EOR (End Of Transmission) 4 Reserved Reserved 3 Send EOR after low- 0: Send DCN (Redial) est speed 1: Send EOR_xxx (Germany PTT) 2 TCF transmission 1 timing after DCS Description (ms) 70 Bit 2 0 80 0 90 1 Bit 1 0 1 0 Initial Setting Bit HEX 18 4 0 1 0 1 0 00 0 100 0 1 0 1 • Bit 1 to 2: Delay time from FSK mode to PSK mode, this is used for G3 mode only, V.34 does not need this setting. • Bit 6 to 7: If level reads "1", machine. Will go down to next lower speed for next data phase. Adjustment / Setting 192