Konica Minolta bizhub 160 Service Manual - Page 224
Soft Switch: #10
View all Konica Minolta bizhub 160 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 224 highlights
bizhub 160/160f bizhub 161/161f Field Service Ver. 1.0 Apr. 2005 16.8.10 SOFT SWITCH: #10 16. Soft Switch Set (bizhub 160f/bizhub 161f only) Bit Designation No. Function Initial Setting Bit HEX 8 Print out RTN page 0: Not to Print 1A report 1: Print Out RTN page report after transaction for TX/ RX RTN signal 7 Confirmation report 0: Print "OK" 0 result field 1: Print "NG" in case of sending or receiving RTN signal 6 Get gap time 5 between digit for pulse dial 1 Value (ms) 550 650 750 850 Bit 6 0 0 1 1 0 Bit 5 0 1 0 1 4 RX PIP T.30 com- 0: Send DCS at current speed mand after send out 1: Return to Tx phase B waiting for DIS signal MPS command 3 Received DIS signal 0: Repeat sending DIS/DTC again until time out within reception 1: Disconnected after sending DCN signal 2 Transmission time 0: No any limitation until document jam limitation 1: Limit to 8 minutes from data phase 1 Audio alarm after 0: Not to alarm after transaction fail communication fail 1: Alarm 3 seconds after disconnected 01 0 0 1 • Bit 8: If this bit set to 1, machine will print out confirmation report after each transaction for TX/RX RTN signal. • Bit 7: If this bit is set to1, the result field will show "NG" instead of "OK" in the confirmation report and activity report or checking the result on the LCD. • Bit 2: For Manual Tx only. Adjustment / Setting 191