Panasonic AJHD1400 AJHD1400 User Guide - Page 14

Rear panel, AC IN inlet, DC IN socket, <Notes&gt, Fuse holder

Page 14 highlights

Parts and their functions (continued) Rear panel HD/SDI IN OUT1 OUT2 SD/SDI DVCPRO /DV TC HD/SD REF IN VIDEO OUT IN 1 Y PB AUDIO OUT OUT PUSH CH1 PUSH CH2 PUSH PUSH L R MONITOR PR AUDIO IN CH1 2 (SUPER) CH2 AUDIO MON OUT ENCODER REMOTE L DC OUT 12V 250mA R R E FUSE 250V T2.5AH M O F1 R T AC IN SIGNAL DC IN GND AC IN inlet This is the AC power inlet. Connect the accessory power cable here. When both an AC power supply and DC power supply have been connected, the AC power supply takes priority. DC IN socket This is the input connector for the DC 12V supply voltage. Use an external DC power supply rated at DC 12 V/7 A (12 A peak or higher) When the voltage has dropped to around 10.6V, the unit's power is automatically turned off. (When "TYPE-A" or "TYPE-B" is not selected as the menu item No.180 BATTERY SEL setting) Even when the supply voltage is restored later, the power will not automatically come back on. The POWER switch must be set to OFF and then back to ON several seconds later. 1 2 3 4 Pin No. 1 2 3 4 Signal Ground - - +12 V External DC adapter If an external DC power supply is used, then check the ratings of the external DC power supply so that they are compatible with those of this unit. Check the pin arrangements of the DC output terminal of the external DC power supply and those of the DC IN socket of this unit so that their polarities are correctly arranged. If +12 V are supplied to the unit's GND terminal by mistake, this may cause fire or injury. If the polarities of the DC IN connectors of other devices are incorrect, and the other devices are connected to the unit by mistake, fire or personal injury may result. z If an external DC power supply is used, then make sure that the external DC power supply is first turned ON, then this unit is turned ON. Improper operation may result in a malfunction in the unit due to slow startup of the output voltage of the external DC power supply. z If input exceeds 18 V by mistake, the protection feature shuts down the power source at around 20 to 35 V. Change the voltage to the regular voltage, and the unit is available. An AC source cannot be connected to this terminal. DC OUT socket This is the DC 12V output socket. Power is supplied from here to the external remote controller (AJ-A95: optional accessory). The DC power cable is packed together with the AJA95. 2 3 1 4 Pin No. 1 2 3 4 Signal Ground - - +12 V Fuse holder This holds the AC 250 V/2.5 A fuse (time lag type). Use the fuse specified by Panasonic. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

14
Parts and their functions
(continued)
Rear panel
AC IN inlet
This is the AC power inlet.
Connect the accessory power cable here.
When both an AC power supply and DC power supply
have been connected, the AC power supply takes
priority.
DC IN socket
This is the input connector for the DC 12V supply
voltage.
Use an external DC power supply rated at DC 12 V/7 A
(12 A peak or higher)
When the voltage has dropped to around 10.6V, the
unit’s power is automatically turned off. (When “TYPE-A”
or “TYPE-B” is not selected as the menu item No.180
BATTERY SEL setting)
Even when the supply voltage is restored later, the
power will not automatically come back on. The POWER
switch must be set to OFF and then back to ON several
seconds later.
<Notes>
If an external DC power supply is used, then make
sure that the external DC power supply is first turned
ON, then this unit is turned ON. Improper operation
may result in a malfunction in the unit due to slow
startup of the output voltage of the external DC power
supply.
If input exceeds 18 V by mistake, the protection
feature shuts down the power source at around 20 to
35 V. Change the voltage to the regular voltage, and
the unit is available. An AC source cannot be
connected to this terminal.
DC OUT socket
This is the DC 12V output socket.
Power is supplied from here to the external remote
controller (AJ-A95: optional accessory).
The DC power cable is packed together with the AJ-
A95.
Fuse holder
This holds the AC 250 V/2.5 A fuse (time lag type).
<Note>
Use the fuse specified by Panasonic.
ENCODER
REMOTE
HD/
S
DI
IN
OUT1
OUT2
S
D/
S
DI
DVCPRO
/DV
MONITOR
L
CH1
CH2
R
AUDIO OUT
OUT
IN
TC
HD/
S
D REF IN
AUDIO IN
CH1
CH2
VIDEO OUT
Y
1
2
P
B
P
R
AUDIO
MON
OUT
(
S
UPER)
L
R
DC OUT
FU
S
E 250V T2.5AH
F1
AC IN
DC IN
R
E
M
O
R
T
PU
S
H
PU
S
H
PU
S
H
PU
S
H
12V 250mA
S
IGNAL
GND
1
2
3
4
Pin No.
Signal
1
Ground
2
3
4
+12 V
External DC adapter
If an external DC power supply is used, then check the
ratings of the external DC power supply so that they are
compatible with those of this unit. Check the pin
arrangements of the DC output terminal of the external DC
power supply and those of the DC IN socket of this unit so
that their polarities are correctly arranged.
If +12 V are supplied to the unit’s GND terminal by
mistake, this may cause fire or injury.
If the polarities of the DC IN connectors of other devices
are incorrect, and the other devices are connected to the
unit by mistake, fire or personal injury may result.
3
1
2
4
Pin No.
Signal
1
Ground
2
3
4
+12 V