Panasonic AJHD1400 AJHD1400 User Guide - Page 42

Mode To Frm, Aj-hdc27f, H

Page 42 highlights

Setup menus (continued) OPERATION (continued) No./Item Description of setting 155*1 AUTO REC For setting whether the recording/stop is executed automatically in conjunction with the Recording Mark of the HD SDI input signals from our camera recorder or not. 0000 OFF : Do not to execute the recording/stop automatically. 0001 TYPE1 : To execute the recording/stop automatically in conjunction with the Recording Mark in the LTC information added to the HD SDI. 0002 TYPE2 : To execute the recording/stop automatically in conjunction with the Recording Mark in the SVITC information added to the HD SDI. z Set the LOCAL/REMOTE switch to the REMOTE position. z For the selection of TYPE 1 or TYPE 2, refer to "Our camera recorder, Recording format, and Recording Mark." z To select TYPE 1 or TYPE 2 to start recording automatically, set this unit to the REC PAUSE mode. It may not operate in any mode other than the REC PAUSE mode. After accepting the auto stop, this unit changes to the REC PAUSE mode. z When this unit is recording in normal operation, the AUTO REC function is not available. *1 Displayed menus may vary depending on the settings in menu No. 25 SYSTEM FREQ. For details, refer to "Menus which are displayed" (page 32). Our camera recorder, Recording format, and Recording Mark Model Recording format Recording Mark TYPE Remarks AJ-HDC27F, H 720/¢¢p over 60p TYPE1 ʔ AJ-HDX400 1080/59.94i -*2 AJ-HDX400E AJ-HDX900 1080/50i 1080/25p over 50i 720/59.94p 720/23.98p over 59.94p 720/29.97p over 59.94p 1080/59.94i 1080/23.98p over 59.94i 1080/29.97p over 59.94i 1080/50i 1080/25p over 50i 720/50p -*2 -*2 TYPE1 TYPE1 TYPE1 -*2 TYPE2 -*2 -*2 -*2 TYPE1 It is possible to switch between TYPE 1 and TYPE 2. TYPE-1 and TYPE-2 are the initial settings for the camera recorder. If the unit is used with the TYPE-1 settings, set the UB MODE of the camera to "FRM RATE". If it is used with the TYPE-2 settings, set the VITC UB MODE to "FRM RATE." 720/25p over 50p TYPE1 *2 In the initial settings, the Recording Mark is not overlapped on the HD SDI signals. No./Item Description of setting 160 MEMORY MODE For setting the repeat playback mode. 0000 OFF : No repeat playback (normal operation). 0001 M-STOP : The tape stops near the BEGIN point when it is fast forwarded or rewound. 0002 REPT1 : When the tape reaches the END point, it is rewound to the BEGIN point, and stops. 0003 CONT : When the tape reaches the END point, it is rewound to the BEGIN point, and plays back, and this is done repeatedly. 161 CTL BGN or TC BGN For setting the BEGIN point in the repeat playback mode. Either TC or CTL is set as the counter display mode using the COUNTER button. If no mode is set appears, and the tape start serves as the BEGIN point. 162 For setting the END point in the repeat playback mode. END Either TC or CTL is set as the counter display mode using the COUNTER button. If no mode is set appears, and the tape end serves as the END point. 163 REPT MODE For setting what images are to be output while the tape returns to the BEGIN point in the repeat playback mode. 0000 FREEZE : The tape returns to the BEGIN point with the image played back at the END point still frozen. 0001 BLACK : The tape returns to the BEGIN point while the screen remains black. 0002 MENU : The tape returns to the BEGIN point following the the settings in menu No. 140 OUTPUT. If the tape end is set as the END point when "FREEZE" is selected, the playback image will not be frozen properly. Set the END point to a place within the range where images are recorded. 180 BATTERY SEL For setting the type of battery. 0000 NiCd12 : Settings for 1 pc. 12 V battery (NEAR: 11.2 V, END: 10.6 V) 0001 NiCd13 : Settings for 1 pc. 13 V battery (NEAR: 12.0 V, END: 10.6 V) 0002 NiCd14 : Settings for 1 pc. 14 V battery (NEAR: 13.6 V, END: 10.6 V) 0003 S-LION : Settings for 1 pc. lithium-ion battery "BP-L90A". (NEAR: 11.7 V, END: 10.6 V) 0004 I-LION : Settings for 1 pc. lithium-ion battery "ENDURA80". (NEAR: 12.9 V, END: 12.4 V) 0005 TYPE-A : Setting for using the battery selected by the menu item No.181 TYPE-A NEAR item and No.182 TYPE-A END item 0006 TYPE-B : Setting for using the battery selected by the menu item No.183 TYPE-B NEAR item and No.184 TYPE-B END item "_____" indicates the factory setting. 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

42
Setup menus
(continued)
OPERATION (continued)
*1
Displayed menus may vary depending on the settings in
menu No. 25 SYSTEM FREQ. For details, refer to
“Menus which are displayed” (page 32).
*2 In the initial settings, the Recording Mark is not
overlapped on the HD SDI signals.
“_____” indicates the factory setting.
No./Item
Description of setting
155*
1
AUTO REC
For setting whether the recording/stop is executed
automatically in conjunction with the Recording Mark
of the HD SDI input signals from our camera recorder
or not.
0000
OFF
:
Do not to execute the recording/stop automatically.
0001
TYPE1 :
To execute the recording/stop automatically in
conjunction with the Recording Mark in the LTC
information added to the HD SDI.
0002
TYPE2 :
To execute the recording/stop automatically in
conjunction with the Recording Mark in the SVITC
information added to the HD SDI.
<Notes>
Set the LOCAL/REMOTE switch to the REMOTE
position.
For the selection of TYPE 1 or TYPE 2, refer to
“Our camera recorder, Recording format, and
Recording Mark.”
To select TYPE 1 or TYPE 2 to start recording
automatically, set this unit to the REC PAUSE
mode. It may not operate in any mode other than
the REC PAUSE mode. After accepting the auto
stop, this unit changes to the REC PAUSE mode.
When this unit is recording in normal operation, the
AUTO REC function is not available.
Our camera recorder, Recording format, and Recording Mark
Model
Recording format
Recording
Mark TYPE
Remarks
AJ-HDC27F, H
720/
¢¢
p over 60p
TYPE1
AJ-HDX400
1080/59.94i
*
2
It is possible to
switch between
TYPE 1 and
TYPE 2.
TYPE-1
and TYPE-2 are
the initial
settings for the
camera recorder.
If the unit is used
with the TYPE-1
settings, set the
UB MODE of the
camera to “FRM
RATE”.
If it is
used with the
TYPE-2 settings,
set the VITC UB
MODE to “FRM
RATE.”
AJ-HDX400E
1080/50i
*
2
1080/25p over 50i
*
2
AJ-HDX900
720/59.94p
TYPE1
720/23.98p over 59.94p
TYPE1
720/29.97p over 59.94p
TYPE1
1080/59.94i
*
2
1080/23.98p over 59.94i
TYPE2
1080/29.97p over 59.94i
*
2
1080/50i
*
2
1080/25p over 50i
*
2
720/50p
TYPE1
720/25p over 50p
TYPE1
No./Item
Description of setting
160
MEMORY
MODE
For setting the repeat playback mode.
0000
OFF
:
No repeat playback (normal operation).
0001
M-STOP :
The tape stops near the BEGIN point when it is fast
forwarded or rewound.
0002
REPT1 :
When the tape reaches the END point, it is
rewound to the BEGIN point, and stops.
0003
CONT :
When the tape reaches the END point, it is
rewound to the BEGIN point, and plays back, and
this is done repeatedly.
161
CTL BGN
or
TC BGN
For setting the BEGIN point in the repeat playback
mode.
Either TC or CTL is set as the counter display mode
using the COUNTER button.
If no mode is set, – – : – – : – – : – – appears, and the
tape start serves as the BEGIN point.
162
END
For setting the END point in the repeat playback mode.
Either TC or CTL is set as the counter display mode
using the COUNTER button.
If no mode is set, – – : – – : – – : – – appears, and the
tape end serves as the END point.
163
REPT MODE
For setting what images are to be output while the
tape returns to the BEGIN point in the repeat
playback mode.
0000
FREEZE
:
The tape returns to the BEGIN point with the image
played back at the END point still frozen.
0001
BLACK :
The tape returns to the BEGIN point while the
screen remains black.
0002
MENU :
The tape returns to the BEGIN point following the
the settings in menu No. 140 OUTPUT.
<Note>
If the tape end is set as the END point when
“FREEZE” is selected, the playback image will not be
frozen properly.
Set the END point to a place within the range where
images are recorded.
180
BATTERY
SEL
For setting the type of battery.
0000
NiCd12
:
Settings for 1 pc. 12 V battery (NEAR: 11.2 V,
END: 10.6 V)
0001
NiCd13 :
Settings for 1 pc. 13 V battery (NEAR: 12.0 V,
END: 10.6 V)
0002
NiCd14 :
Settings for 1 pc. 14 V battery (NEAR: 13.6 V,
END: 10.6 V)
0003
S-LION :
Settings for 1 pc. lithium-ion battery “BP-L90A”.
(NEAR: 11.7 V, END: 10.6 V)
0004
I-LION :
Settings for 1 pc. lithium-ion battery “ENDURA80”.
(NEAR: 12.9 V, END: 12.4 V)
0005
TYPE-A :
Setting for using the battery selected by the menu
item No.181 TYPE-A NEAR item and No.182
TYPE-A END item
0006
TYPE-B :
Setting for using the battery selected by the menu
item No.183 TYPE-B NEAR item and No.184
TYPE-B END item