Panasonic WJHD200 WJHD200 User Guide - Page 37
Alarm Data ALARM DATA exclusive, Control Unit Address CTL-UNIT
![]() |
View all Panasonic WJHD200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
G Baud Rate (BAUD RATE) 1. Move the cursor to BAUD RATE with the [D] or [C] button. 2. Select the rate with the JogDial, and press the JogDial. The default value is 9600 bits per second. 4800: 4 800 bps 9600: 9 600 bps* 19200: 19 200 bps G Data Bit (DATA BIT) 1. Move the cursor to DATA BIT with the [D] or [C] button. 2. Select the bit length with the JogDial. The default value is 8 bits. 7: 7 bits* ; select when using RS-232C protocol. 8: 8 bits G Parity Check (PARITY CHECK) 1. Move the cursor to PARITY CHECK with the [D] or [C] button. 2. Select the check mode with the JogDial. The default is NONE. NONE: No parity check EVEN: Even parity ODD: Odd parity* G Stop Bit (STOP BIT) 1. Move the cursor to STOP BIT with the [D] or [C] button. 2. Select the number of stop bits with the JogDial. The default is 1. 1: 1 bit* 2: 2 bits G Wait Time (WAIT TIME) The unit retransmits data after waiting the specified time if there is no response from the connected device. 1. Move the cursor to WAIT TIME with the [D] or [C] button. 2. Select the waiting time with the JogDial. The default is OFF. OFF: Retransmission is disabled. * 100MS: 100 m seconds 200MS: 200 m seconds 1S: 1 second G Control Unit Address (CTL-UNIT ADDRESS) (only for PS •DATA) When the recorder performs as a controller in the system, the unit address can be set from the setup menu on the monitor. 1. Move the cursor to CTL-UNIT ADDRESS with the [D] or [C] button. 2. Select the address with the JogDial. The default value is 1. Assignable address: From 1 to 99, must be unique in the chain. Note: Assign an address except 1 to WJ-HD200 when using a system controller in the system. G System Unit Address (SYS-UNIT ADDRESS) (exclusive to PS •DATA) When the recorder performs as a system unit, the unit address can be set from the setup menu on the monitor. 1. Move the cursor to SYS-UNIT ADDRESS with the [D] or [C] button. 2. Select the address with the JogDial. The default value is 1. Assignable address: From 1 to 99, must be unique in the chain. G Alarm Data (ALARM DATA) (exclusive to PS •DATA) The recorder pauses before sending a notice to the connected system controller when an alarm operates. 1. Move the cursor to ALARM DATA with the [D] or [C] button. 2. Select the parameter with the JogDial, and press the JogDial. The default is 1S. OFF: Select this when no system controller is connected. 0S: Does not pause. 1S: Pauses 1 second. 5S: Pauses 5 seconds. 37
![](/manual_guide/products/panasonic-wjhd200-wjhd200-user-guide-d198673/37.png)