Panasonic WJHD200 WJHD200 User Guide - Page 64
Communication Setup, Serial Port Setup, CONTROL UNIT ADDRESS only for PS
![]() |
View all Panasonic WJHD200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
I Communication Setup (COMMUNICATION SETUP) 8 Parity Check (PARITY CHECK) NONE: No parity check EVEN: Even parity ODD: Odd parity Click the [SERIAL PORT SETUP] or [NETWORK SETUP] button. The respective window opens. I Serial Port Setup (SERIAL PORT SETUP) 8 Stop Bit (STOP BIT) 1 bit: 1 bit 2 bit: 2 bits 8 Wait Time (WAIT TIME) OFF: Retransmission is disabled. 100 MSEC: 100 m seconds 200 MSEC: 200 m seconds 1 SEC: 1 second 8 System Unit Address (SYSTEM UNIT ADDRESS) (only for PS•DATA) Assignable addresses: From 1 to 99, must be unique in the chain. 8 Control Unit Addresses (CONTROL UNIT ADDRESS) (only for PS•DATA) Assignable address: From 1 to 99, must be unique in the chain. 8 Protocol Selection (PROTOCOL SELECT) PS•DATA: Select when the communication chain uses the PS•DATA protocol. When selected, the DATA terminal on the rear panel can be used. RS-232C: Select when other than PS•DATA is used. When selected, the RS-232C terminal on the rear panel can be used. 8 Alarm Data (ALARM DATA) OFF: Select this when no system controller is connected. 0 SEC: Does not pause. 1 SEC: Pauses for 1 second. 5 SEC: Pauses for 5 seconds. Click the [SET] button when all items have been set properly. Click the [CAMERA NO. SETUP] button. The CAMERA NUMBER SETUP window opens. 8 Baud Rate (BAUD RATE) 4800: 4 800 bps 9600: 9 600 bps 19200: 19 200 bps 8 Data Bit (DATA BIT) 7: 7 bits 8: 8 bits 64