Page 101 highlights
PDG-DHT8000L Expand Serial Command Functional Specifications 10.2.2. When the command pipelining is needed When it needs command pipelining, the operation is the same as the remote control as below: 1) Sending-side system issues commands every 100ms 2) When receiving an applicable command, the function is executed repeatedly for 120ms. 3) When receiving the same command in a row within 120ms, the function is repeatedly executed for another 120ms from the moment of the second command reception. 4) When there is no incoming command after 120ms, the execution of pipelining is stopped. 5) When the projector receives other command within 120ms, the execution of pipelining is stopped. 10.3. Status Read Command with Address 10.3.1. Format 1) PC issues a command in the format as below: "A" Address "CR" Command [CR] or "A" Address "CR_" Command [CR] Address: 3-digit number ("001" - "999") Command: string (Refer to Basic and Expand Serial Commands) 2) The only projectors that have the address matching with the one in the received data decode the command, and it returns required data. Required Data [CR] Required Data: String (Refer to Basic Status Read Commands) 3) When the received data cannot be decoded, it returns "? " [CR] 101/101