Sanyo PDG-DHT8000L RS232C Expand - Page 50

CF_FANSPEED Command, 9.42 CF_RCODE Command, 9.43 CF_RSENS Command

Page 50 highlights

PDG-DHT8000L Expand Serial Command Functional Specifications 8.9.41 CF_FANSPEED Command Command "CF_FANSPEED_%1" [CR] %1 "MAX Select Maximum speed of Fan Control "NOR Select Normal speed of Fan Control Details Switch Fan Control Speed. (Valid only when in the normal Power ON status.) The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.42 CF_RCODE Command Command "CF_RCODE_%1" [CR] "001 Select Code 1 "002 Select Code 2 "003 Select Code 3 "004 Select Code 4 %1 "005 Select Code 5 "006 Select Code 6 "007 Select Code 7 "008 Select Code 8 "UP Switch forward (Code1→Code2→Code3 - - - →Code8→Code1) "DN" --------- Switch backward (Code8→Code7→Code6 - - -→Code1→Code8) Details Select Remote Control Code (Valid only when in the normal Power ON status) The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.9.43 CF_RSENS Command Command "CF_RSENS_%1" [CR] "ALL Select all receiver of projector "FRONTTOP Select both front and top receiver of projector "BACKTOP Select both back and top receiver of projector "FRONTBACK Select both front and back receiver of projector "FRONT Select only front receiver of projector %1 "TOP Select only top receiver of projector "BACK Select only back receiver of projector "UP Switch forward (ALL → FRONTTOP→BACKTOP→ FRONTBACK→ FRONT →TOP → BACK→ALL) "DN Switch backward (BACK →TOP→FRONT→FRONTBACK→ BACKTOP →FRONTTOP→ ALL→BACK) Details Select location of infrared remote receiver of remote control (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 50/101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

PDG-DHT8000L
Expand Serial Command Functional Specifications
50/101
8.9.41 CF_FANSPEED Command
Command
“CF_FANSPEED_%1” [CR]
%1
“MAX” ---------------------------- Select Maximum speed of Fan Control
“NOR” ---------------------------- Select Normal speed of Fan Control
Details
Switch Fan Control Speed. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.42 CF_RCODE Command
Command
“CF_RCODE_%1” [CR]
%1
“001” ------------------------------------ Select Code 1
“002” ------------------------------------ Select Code 2
“003” ------------------------------------ Select Code 3
“004” ------------------------------------ Select Code 4
“005” ------------------------------------ Select Code 5
“006” ------------------------------------ Select Code 6
“007” ------------------------------------ Select Code 7
“008” ------------------------------------ Select Code 8
“UP” ---------- Switch forward (Code1
Code2
Code3 - - -
Code8
Code1)
“DN” --------- Switch backward (Code8
Code7
Code6 - - -
Code1
Code8)
Details
Select Remote Control Code (Valid only when in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.43 CF_RSENS Command
Command
“CF_RSENS_%1” [CR]
%1
“ALL” -------------------------- Select all receiver of projector
“FRONTTOP” ---------------- Select both front and top receiver of projector
“BACKTOP” ------------------ Select both back and top receiver of projector
“FRONTBACK” -------------- Select both front and back receiver of projector
“FRONT” ---------------------- Select only front receiver of projector
“TOP” -------------------------- Select only top receiver of projector
“BACK” ------------------------ Select only back receiver of projector
“UP” ---------------- Switch forward (ALL
FRONTTOP
BACKTOP
FRONTBACK
FRONT
TOP
BACK
ALL)
“DN” ---------------- Switch backward (BACK
TOP
FRONT
FRONTBACK
BACKTOP
FRONTTOP
ALL
BACK)
Details
Select location of infrared remote receiver of remote control (Available only in the
normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]