Sanyo PDG-DHT8000L RS232C Expand - Page 51

CF_P-MANE Command, 9.45 CF_P-MANETIME Command, 9.46 CF_ON-STA Command

Page 51 highlights

PDG-DHT8000L Expand Serial Command Functional Specifications 8.9.44 CF_P-MANE Command Command "CF_P-MANE_%1" [CR] "OFF Set Power Management to Off "READY Set Power Management to Ready %1 "SHUTDOWN Set Power Management to Shut Down mode "UP Switch forward (Off→Ready→Shut down→Off) "DN Switch backward (Off→Shut down→Ready→Off) Details Set/Cancel Power Management. (Valid only when in the normal Power ON status.) The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.45 CF_P-MANETIME Command Command "CF_P-MANETIME_%1" [CR] "01" - "30 Directly specify setting time by the minute "UP Increment value by 1 %1 (Switched in 01→02→ --- → 30 → 01 order) "DN Decrement value by 1 (Switched in 30→29→ --- → 01 → 30 order) Details Set time of Power Management time (Available only in the normal Power ON status). The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.46 CF_ON-STA Command Command "CF_ON-STA_%1" [CR] "ON Set Power On Start to ON. "OFF Set Power On Start to OFF. %1 "UP Toggle between ON and OFF.(On→Off→On → - - -) "DN Toggle between ON and OFF.(On→Off→On → - - -) *"UP" and "DN" are exactly same operation. Details Set/Cancel Power ON Start (Only valid when it is in the normal Power ON status) The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 51/101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

PDG-DHT8000L
Expand Serial Command Functional Specifications
51/101
8.9.44 CF_P-MANE Command
Command
“CF_P-MANE_%1” [CR]
%1
“OFF” ---------------------------------- Set Power Management to Off
“READY” ----------------------------- Set Power Management to Ready
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
“UP” ----------------------- Switch forward (Off
Ready
Shut down
Off)
“DN” ---------------------- Switch backward (Off
Shut down
Ready
Off)
Details
Set/Cancel Power Management. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.45 CF_P-MANETIME Command
Command
“CF_P-MANETIME_%1” [CR]
%1
“01” - ”30” ----------------------- Directly specify setting time by the minute
“UP” ------------------------------- Increment value by 1
(Switched in 01
02
---
30
01 order)
“DN” ------------------------------ Decrement value by 1
(Switched in 30
29
---
01
30 order)
Details
Set time of Power Management time (Available only in the normal Power ON
status). The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.46 CF_ON-STA Command
Command
“CF_ON-STA_%1” [CR]
%1
“ON” --------------------------- Set Power On Start to ON.
“OFF” ------------------------- Set Power On Start to OFF.
“UP” --------------------------- Toggle between ON and OFF.(On
Off
On
- - -)
“DN” --------------------------- Toggle between ON and OFF.(On
Off
On
- - -)
*”UP” and “DN” are exactly same operation.
Details
Set/Cancel Power ON Start (Only valid when it is in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]