Sanyo PDG-DHT8000L RS232C Expand - Page 43

CF_PIPMODEFREE Command, 9.16 CF_PIPRST Command, 9.17 CF_EDGEBLENDING Command, 9.18 CF_BLEND

Page 43 highlights

PDG-DHT8000L Expand Serial Command Functional Specifications 8.9.15 CF_PIPMODEFREE Command Command "CF_PIPMODEFREE_%1" [CR] "USER1 Set User1 to Free status "USER 2 Set User2 to Free status %1 "USER 3 Set User3 to Free status "USER 4 Set User4 to Free status "USER 5 Set User5 to Free status Details Delete the data registered in Custom User1-5 and returns it to Free status. This command operates the same way as resetting to User1-5 in "Picture in Picture" Menu. (Available only in the normal Power ON status) *When there is only one user mode of stored state, return "101" [CR] Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.16 CF_PIPRST Command Command "CF_PIPRST_%1" [CR] %1 "RST Reset current setting status Details Reset current setting status of "Picture in Picture". (Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.17 CF_EDGEBLENDING Command Command "CF_EDGEBLENDING_%1" [CR] %1 "ON Set Edge blending to On "OFF Set Edge blending to Off Details Set Edge blending.(Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.18 CF_BLEND Command Command "CF_BLEND_%1_%2" [CR] "LEFT Left side %1 "RIGHT Right side "TOP Upper side "BOTTOM Lower side "000"-"960 Directly specify value of direction of %1 *Value of upper limit changes by choice of %1 %2 Left 000~960 Right 000~960 Top 000~540 Bottom 000~540 Details Set value of direction specified by Edge blending %1. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 43/101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

PDG-DHT8000L
Expand Serial Command Functional Specifications
43/101
8.9.15 CF_PIPMODEFREE Command
Command
“CF_PIPMODEFREE_%1” [CR]
%1
“USER1” --------------------------- Set User1 to Free status
“USER 2” -------------------------- Set User2 to Free status
“USER 3” -------------------------- Set User3 to Free status
“USER 4” -------------------------- Set User4 to Free status
“USER 5” -------------------------- Set User5 to Free status
Details
Delete the data registered in Custom User1–5 and returns it to Free status.
This command operates the same way as resetting to User1-5 in “Picture in
Picture” Menu.
(Available only in the normal Power ON status)
*When there is only one user mode of stored state, return “101” [CR]
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.16 CF_PIPRST Command
Command
“CF_PIPRST_%1” [CR]
%1
“RST” ---------------------- Reset current setting status
Details
Reset current setting status of “Picture in Picture”.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.17 CF_EDGEBLENDING Command
Command
“CF_EDGEBLENDING_%1” [CR]
%1
“ON” ---------------------- Set Edge blending to On
“OFF” -------------------- Set Edge blending to Off
Details
Set Edge blending.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.18 CF_BLEND Command
Command
“CF_BLEND_%1_%2” [CR]
%1
“LEFT” ---------------------- Left side
“RIGHT” -------------------- Right side
“TOP” ----------------------- Upper side
“BOTTOM” ---------------- Lower side
%2
“000”-“960”-------------------- Directly specify value of direction of %1
*Value of upper limit changes by choice of %1
Left ---------------------- 000~960
Right -------------------- 000~960
Top ---------------------- 000~540
Bottom ----------------- 000~540
Details
Set value of direction specified by Edge blending %1.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]