Sanyo PDG-DHT8000L RS232C Expand - Page 37

Lamp Command, 8.1 CF_LAMPMODE Command, 8.2 CF_AUTOLAMPCONTRL Command, 8.3 CF_LAMPLIFECONTRL Command

Page 37 highlights

PDG-DHT8000L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command "CF_LAMPMODE_%1" [CR] "FULL Set lamp mode to 2-lamp (FULL) %1 "LAMP1 Set lamp1 mode "LAMP2 Set lamp2 mode Details Select Lamp mode. (Valid only when in the normal Power ON status.) The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.8.2 CF_AUTOLAMPCONTRL Command Command "CF_AUTOLAMPCONTRL_%1" [CR] "NORMAL Set lamp control mode to NORMAL %1 "ECO1 Set lamp control mode to ECO1 "ECO2 Set lamp control mode to ECO2 Details Select Lamp control mode. (Valid only when in the normal Power ON status.) The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.8.3 CF_LAMPLIFECONTRL Command Command "CF_LAMPLIFECONTRL_%1" [CR] %1 "MODE1 Set Lamp life control mode to Mode1 "MODE2 Set Lamp life control mode to Mode2 Details Select Lamp life control. (Valid only when in the normal Power ON status.) The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.8.4 CF_LAMPINTERVAL Command Command "CF_LAMPINTERVAL_%1" [CR] "AUTO Set Lamp interval to Auto "0024 Set Lamp interval to 24 hours "0200 Set Lamp interval to 200 hours %1 "0500 Set Lamp interval to 500 hours "1000 Set Lamp interval to 1000 hours "2000 Set Lamp interval to 2000 hours "OFF Set Lamp interval to OFF Details Select Lamp interval. (Valid only when in the normal Power ON status.) The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 37/101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

PDG-DHT8000L
Expand Serial Command Functional Specifications
37/101
8.8
Lamp Command
8.8.1 CF_LAMPMODE Command
Command
“CF_LAMPMODE_%1” [CR]
%1
“FULL” --------------------------- Set lamp mode to 2-lamp (FULL)
“LAMP1” ------------------------- Set lamp1 mode
“LAMP2” ------------------------- Set lamp2 mode
Details
Select Lamp mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.2 CF_AUTOLAMPCONTRL Command
Command
“CF_AUTOLAMPCONTRL_%1” [CR]
%1
“NORMAL” --------------------- Set lamp control mode to NORMAL
“ECO1” -------------------------- Set lamp control mode to ECO1
“ECO2” -------------------------- Set lamp control mode to ECO2
Details
Select Lamp control mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.3 CF_LAMPLIFECONTRL Command
Command
“CF_LAMPLIFECONTRL_%1” [CR]
%1
“MODE1” -------------------------- Set Lamp life control mode to Mode1
“MODE2” -------------------------- Set Lamp life control mode to Mode2
Details
Select Lamp life control. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.4 CF_LAMPINTERVAL Command
Command
“CF_LAMPINTERVAL_%1” [CR]
%1
“AUTO” ------------------------- Set Lamp interval to Auto
“0024” --------------------------- Set Lamp interval to 24 hours
“0200” --------------------------- Set Lamp interval to 200 hours
“0500” --------------------------- Set Lamp interval to 500 hours
“1000” --------------------------- Set Lamp interval to 1000 hours
“2000” --------------------------- Set Lamp interval to 2000 hours
“OFF” ---------------------------- Set Lamp interval to OFF
Details
Select Lamp interval. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]