PDG-DHT8000L Expand Serial Command Functional Specifications 9.11.5 CR_P-TIMER Command Command "CR_P-TIMER" [CR] Details Get Presentation Timer operating status Acceptable "000_%1" [CR] "ON Presentation Timer is ongoing. Response %1 "STOP Presentation Timer is paused. "OFF Presentation Timer is not active. Unacceptable "?" [CR] 9.11.6 CR_TEMPWARN Command Command "CR_TEMPWARN" [CR] Details Get the information about the temperature inside the projector (close to the abnormal or in the abnormal status/in the safe temperature level/abnormal status is not detected). It is possible to get the information about more than one sensor all at once if it is applicable. Acceptable "000_%1" [CR] "*_*" Sensor 1 data comes first, and then one space, after that sensor 2 data is followed. Each data is as below: "W"--- in or close to the abnormal temp. (Warning Temp.) Response %1 "S"--- in the safe level of temperature (Safe Temp.). "N"--- the given sensor does not detect abnormal temp. e.g. "S_W" [CR] indicates that the temperature detected at Sensor 1 is in the safe level while Sensor 2 in the abnormal temperature. Unacceptable "?" [CR] 96/101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

PDG-DHT8000L
Expand Serial Command Functional Specifications
96/101
9.11.5 CR_P-TIMER Command
Command
“CR_P-TIMER” [CR]
Details
Get Presentation Timer operating status
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------------- Presentation Timer is ongoing.
”STOP” ------------------------ Presentation Timer is paused.
“OFF” -------------------------- Presentation Timer is not active.
Response
Unacceptable
“?” [CR]
9.11.6 CR_TEMPWARN Command
Command
“CR_TEMPWARN” [CR]
Details
Get the information about the temperature inside the projector (close to the
abnormal or in the abnormal status/in the safe temperature level/abnormal status
is not detected).
It is possible to get the information about more than one sensor all at once if it is
applicable.
Acceptable
“000_%1” [CR]
%1
“*_*”
Sensor 1 data comes first, and then one space, after that sensor
2 data is followed.
Each data is as below:
“W”--- in or close to the abnormal temp. (Warning Temp.)
“S”--- in the safe level of temperature (Safe Temp.).
“N”--- the given sensor does not detect abnormal temp.
e.g. “S_W” [CR] indicates that the temperature detected at
Sensor 1 is in the safe level while Sensor 2 in the abnormal
temperature.
Response
Unacceptable
“?” [CR]